| Literature DB >> 10745446 |
G Casella1, F Werner, V Klauss, H Mudra.
Abstract
We report a case of successful treatment of coronary artery perforation and cardiac tamponade, which developed during percutaneous transluminal coronary angioplasty, with a PTFE-coated stent. Intravascular ultrasound was first used to overcome the shortcomings of conventional angiography and overlapping of a conventional stent was not as effective as coated-stent placement in sealing a further leakage. Thus, PTFE-coated stents may be an effective alternative to emergency surgery or autologous venous covered stenting and should be considered when coronary artery perforation occurs.Entities:
Mesh:
Substances:
Year: 1999 PMID: 10745446
Source DB: PubMed Journal: J Invasive Cardiol ISSN: 1042-3931 Impact factor: 2.022