Literature DB >> 10745297

A new method for quantitative ultrasound measurements at multiple skeletal sites: first results of precision and fracture discrimination.

R Barkmann1, E Kantorovich, C Singal, D Hans, H K Genant, M Heller, C C Glüer.   

Abstract

We investigated a new multisite quantitative ultrasound device that measures the acoustic velocity in axial transmission mode along the cortex. Using a prototype of the Omnisense (Sunlight Ultrasound Technologies, Rehovot, Israel), we tested the performance of this instrument at four sites of the skeleton: radius, ulna, metacarpal, and phalanx. Intraobserver (interobserver) precision errors ranged from 0.2% to 0.3% (0.3% to 0.7%) for triplicate measurements with repositioning. Fracture discrimination was tested by comparing a group of 34 women who had previously suffered a fracture of the hip, spine, ankle, or forearm to a group of 28 healthy women who had not suffered a fracture. Age-adjusted standardized odds ratios ranged from 1.6 to 4.5. Except for the ulna the sites showed a significant fracture discrimination (p < 0.01). The areas under the receiver operating curves (ROC) curves were from 0.88 to 0.89 for radius, metacarpal, and phalanx. A combination of the results from the three sites showed a significant increase of the ROC area to 0.95 (p < 0. 05). Our results show promising performance of this new device. The ability to measure a large variety of sites and the potential to combine these measurements are promising with regard to optimizing fracture risk assessment.

Entities:  

Keywords:  Non-programmatic

Mesh:

Year:  2000        PMID: 10745297     DOI: 10.1385/jcd:3:1:001

Source DB:  PubMed          Journal:  J Clin Densitom        ISSN: 1094-6950            Impact factor:   2.963


  24 in total

1.  Can geometry-based parameters from pQCT and material parameters from quantitative ultrasound (QUS) improve the prediction of radial bone strength over that by bone mass (DXA)?

Authors:  M Hudelmaier; V Kuhn; E M Lochmüller; H Well; M Priemel; T M Link; F Eckstein
Journal:  Osteoporos Int       Date:  2004-01-22       Impact factor: 4.507

2.  Low-frequency axial ultrasound velocity correlates with bone mineral density and cortical thickness in the radius and tibia in pre- and postmenopausal women.

Authors:  V Kilappa; P Moilanen; L Xu; P H F Nicholson; J Timonen; S Cheng
Journal:  Osteoporos Int       Date:  2010-06-25       Impact factor: 4.507

Review 3.  [Quantitative ultrasound].

Authors:  R Barkmann; C-C Glüer
Journal:  Radiologe       Date:  2006-10       Impact factor: 0.635

Review 4.  An update on the assessment of osteoporosis using radiologic techniques.

Authors:  John Damilakis; Thomas G Maris; Apostolos H Karantanas
Journal:  Eur Radiol       Date:  2006-11-28       Impact factor: 5.315

5.  Longitudinal monitoring of bone accretion measured by quantitative multi-site ultrasound (QUS) of bones in patients with delayed puberty (a pilot study).

Authors:  Zvi Zadik; Tali Sinai; Ella Borondukov; Amnon Zung; Irit Yaniv; Ram Reifen
Journal:  Osteoporos Int       Date:  2004-12-23       Impact factor: 4.507

Review 6.  Quantitative ultrasound in the assessment of skeletal status.

Authors:  Giuseppe Guglielmi; Judith Adams; Thomas M Link
Journal:  Eur Radiol       Date:  2009-03-04       Impact factor: 5.315

7.  Multi-site quantitative ultrasound compared to dual energy X-ray absorptiometry in rheumatoid arthritis: effects of body mass index and inflamed soft tissue on reproducibility.

Authors:  A Pfeil; J Böttcher; H J Mentzel; G Lehmann; M L Schäfer; A Kramer; A Petrovitch; B E Seidl; A Malich; G Hein; G Wolf; W A Kaiser
Journal:  Rheumatol Int       Date:  2006-05-31       Impact factor: 2.631

8.  Differential effects of hormone replacement therapy on bone mineral density and axial transmission ultrasound measurements in cortical bone.

Authors:  K M Knapp; G M Blake; T D Spector; I Fogelman
Journal:  Osteoporos Int       Date:  2003-04-15       Impact factor: 4.507

9.  Bone status in rheumatoid arthritis assessed at peripheral sites by three different quantitative ultrasound devices.

Authors:  O R Madsen; C Suetta; C Egsmose; J S Lorentzen; O H Sørensen
Journal:  Clin Rheumatol       Date:  2004-05-18       Impact factor: 2.980

10.  Pediatric reference curves for multi-site quantitative ultrasound and its modulators.

Authors:  Zvi Zadik; Dario Price; Gary Diamond
Journal:  Osteoporos Int       Date:  2003-08-12       Impact factor: 4.507

View more