Abstract

Digital anatomical models of man and animals are available for use in numerical calculations to predict electromagnetic field (EMF)-induced specific absorption rate (SAR) values. To use these models, permittivity values are assigned to the various tissues for the EMF frequencies of interest. There is, as yet, no consensus on what are the best permittivity data. This study analyzed the variability in published permittivity data and investigated the effects of permittivity values that are proportional on SAR calculations. Whole-sphere averaged and localized SAR values along the diameter of a 4-cm sphere are calculated for EMF exposures in the radio frequency range of 1 MHz to 1 GHz. When the dimensions of a sphere are small compared to the wavelength (i.e., wavelength inside the material is greater than ten times the dimensions of the object), the whole-sphere averaged SAR is inversely proportional to the permittivity of the material composing the sphere. However, the localized SAR values generally do not have the same relation and, as a matter of fact, vary greatly depending on the location within the sphere. These results indicate that care must be taken in choosing the permittivity values used in calculating SAR values and some estimate of the dependence of the calculated SAR values on variability in permittivity should be determined.

Entities:  

Mesh:

Year:  2000        PMID: 10743782     DOI: 10.1109/10.827308

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  4 in total

1.  MRI-based anatomical model of the human head for specific absorption rate mapping.

Authors:  Nikos Makris; Leonardo Angelone; Seann Tulloch; Scott Sorg; Jonathan Kaiser; David Kennedy; Giorgio Bonmassar
Journal:  Med Biol Eng Comput       Date:  2008-11-05       Impact factor: 2.602

2.  Electrical Properties Tomography Based on $B_{{1}}$ Maps in MRI: Principles, Applications, and Challenges.

Authors:  Jiaen Liu; Yicun Wang; Ulrich Katscher; Bin He
Journal:  IEEE Trans Biomed Eng       Date:  2017-08-21       Impact factor: 4.538

3.  Novel Method of Non-contact Remote Measurement of Neuronal Electrical Activity.

Authors:  Tyler A Carson; Hammad Ghanchi; Harjyot Toor; Gohar Majeed; James G Wiginton; Yongming Zhang; Dan E Miulli
Journal:  Cureus       Date:  2018-09-28

4.  Parameter Search Algorithms for Microwave Radar-Based Breast Imaging: Focal Quality Metrics as Fitness Functions.

Authors:  Declan O'Loughlin; Bárbara L Oliveira; Muhammad Adnan Elahi; Martin Glavin; Edward Jones; Milica Popović; Martin O'Halloran
Journal:  Sensors (Basel)       Date:  2017-12-06       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.