Literature DB >> 10743318

A cluster of cases of legionnaires' disease associated with exposure to a spa pool on display.

M McEvoy1, N Batchelor, G Hamilton, A MacDonald, M Faiers, A Sills, J Lee, T Harrison.   

Abstract

Interviews with four apparently sporadic cases of legionnaires' disease identified by laboratory reporting in one health district revealed that three of the four cases had been exposed to a new design of spa pool on display at a retail outlet. The fourth case had been exposed to the same design of spa pool in a private home. None had bathed in the spa pool. Legionella pneumophila serogroup 1 mAB subgroup 'Philadelphia' was isolated from samples taken from both spa pools. The display pool had not been maintained as recommended for a public spa pool in use by bathers. Revised maintenance instructions were issued to all purchasers of these spa pools in the United Kingdom (UK) and overseas. Patients may not remember specific exposures; scrutiny of activity diaries helped to identify exposure to a common location. Even when not in use by bathers, spa pools on display can be a source of legionella infection and should be maintained according to current hygiene guidelines.

Entities:  

Mesh:

Year:  2000        PMID: 10743318

Source DB:  PubMed          Journal:  Commun Dis Public Health        ISSN: 1462-1843


  6 in total

1.  Sporadic cases of community acquired legionnaires' disease: an ecological study to identify new sources of contamination.

Authors:  D Che; B Decludt; C Campese; J C Desenclos
Journal:  J Epidemiol Community Health       Date:  2003-06       Impact factor: 3.710

Review 2.  Current and emerging Legionella diagnostics for laboratory and outbreak investigations.

Authors:  Jeffrey W Mercante; Jonas M Winchell
Journal:  Clin Microbiol Rev       Date:  2015-01       Impact factor: 26.132

3.  Legionellosis Outbreak Associated With a Hotel Fountain.

Authors:  Shamika S Smith; Kathy Ritger; Usha Samala; Stephanie R Black; Margaret Okodua; Loretta Miller; Natalia A Kozak-Muiznieks; Lauri A Hicks; Craig Steinheimer; Saadeh Ewaidah; Lance Presser; Alicia M Siston
Journal:  Open Forum Infect Dis       Date:  2015-12-28       Impact factor: 3.835

4.  Multistate analysis of prospective Legionnaires' disease cluster detection using SaTScan, 2011-2015.

Authors:  Chris Edens; Nisha B Alden; Richard N Danila; Mary-Margaret A Fill; Paul Gacek; Alison Muse; Erin Parker; Tasha Poissant; Patricia A Ryan; Chad Smelser; Melissa Tobin-D'Angelo; Stephanie J Schrag
Journal:  PLoS One       Date:  2019-05-30       Impact factor: 3.240

Review 5.  Biofilms: the stronghold of Legionella pneumophila.

Authors:  Mena Abdel-Nour; Carla Duncan; Donald E Low; Cyril Guyard
Journal:  Int J Mol Sci       Date:  2013-10-31       Impact factor: 5.923

6.  Legionella spp. Risk Assessment in Recreational and Garden Areas of Hotels.

Authors:  Antonios Papadakis; Dimosthenis Chochlakis; Vassilios Sandalakis; Maria Keramarou; Yannis Tselentis; Anna Psaroulaki
Journal:  Int J Environ Res Public Health       Date:  2018-03-26       Impact factor: 3.390

  6 in total