Literature DB >> 10742611

Measurement of peripheral oxygen utilisation in neonates using near infrared spectroscopy: comparison between arterial and venous occlusion methods.

I A Hassan1, S A Spencer, Y A Wickramasinghe, K S Palmer.   

Abstract

The aim of this study was to develop an arterial occlusion method and compare it with the venous occlusion method for measurement of peripheral oxygen utilisation in neonates using near infrared spectroscopy (NIRS). Twenty healthy neonates were studied. Arterial occlusion was produced by inflating a neonatal blood pressure cuff to 100 mmHg for 30-40 s and oxygen utilisation (VO(2)) was calculated using the HbO(2) decrement slope following occlusion. Venous occlusion was produced by inflating the cuff to 30 mmHg for 15-20 s and VO(2) was calculated by: VO(2)=HbTx4x(SaO(2)-SvO(2)), where SaO(2) is the arterial oxygen saturation measured by pulse oximetry and SvO(2) is the venous oxygen saturation measured by NIRS. Each baby had a minimum of three arterial and three venous occlusions. Criteria were developed for acceptance/rejection of an occlusion. Using the arterial method, the mean VO(2) was 1.12 mM cm(-1) O(2)/min (S.D.=0.25), (95% CI=1.00-1.24 mM cm(-1) O(2)/min). The coefficient of variation was 6.6+/-4.1%. Using the venous method, the mean VO(2) was 1.60 mM cm(-1) O(2)/min (S.D.=0.48), (95% CI=1. 38-1.82 mM cm(-1) O(2)/min). The coefficient of variation was 12. 6+/-5.7%. The correlation between the two methods was weak (r=0.28 and r(2) was 0.08). The mean difference between the two methods was 0. 47 mM cm(-1) O(2)/min (S.D.=0.51). The limits of agreement were -0. 53 to 1.47 mM cm(-1) O(2)/min. The arterial method gives more consistent results.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10742611     DOI: 10.1016/s0378-3782(99)00076-6

Source DB:  PubMed          Journal:  Early Hum Dev        ISSN: 0378-3782            Impact factor:   2.079


  5 in total

1.  Effect of limb cooling on peripheral and global oxygen consumption in neonates.

Authors:  I A-A Hassan; Y A Wickramasinghe; S A Spencer
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2003-03       Impact factor: 5.747

2.  Effect of a change in global metabolic rate on peripheral oxygen consumption in neonates.

Authors:  I A-A Hassan; Y A Wickramasinghe; S A Spencer
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2003-03       Impact factor: 5.747

Review 3.  The light still shines, but not that brightly? The current status of perinatal near infrared spectroscopy.

Authors:  S E Nicklin; I A-A Hassan; Y A Wickramasinghe; S A Spencer
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2003-07       Impact factor: 5.747

Review 4.  Transfusion Decision Making in Pediatric Critical Illness.

Authors:  Chris Markham; Sara Small; Peter Hovmand; Allan Doctor
Journal:  Pediatr Clin North Am       Date:  2017-10       Impact factor: 3.278

5.  The Predictive Value of Pulse Oximeters for Pulse Improvement after Angiography in Infants and Children.

Authors:  Mohammad-Reza Alipour; Mazyar Rastegar; Mehdi Ghaderian; Seyedeh-Mahdieh Namayandeh; Reza Faraji; Zohreh Pezeshkpour
Journal:  Iran J Pediatr       Date:  2016-07-10       Impact factor: 0.364

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.