Symptomatic peripheral vascular tree stenosis. Comparison of subtracted and nonsubtracted 3D contrast-enhanced MR angiography with fat suppression.

E Sueyoshi1, I Sakamoto, Y Matsuoka, H Hayashi, K Hayashi.   

Abstract

OBJECTIVE: To determine the clinical feasibility of contrast-enhanced three-dimensional (3D) MR angiography (MRA) with fat suppression spectral inversion at lipids and to compare subtracted and nonsubtracted images.
MATERIAL AND METHODS: In 13 patients suspected of having lower extremity ischemia, 3D dynamic contrast-enhanced MRA of the iliac and femoral arteries was performed using the fat suppression technique. The validity of the MRA interpretations of the degree of stenoses was evaluated by comparing with conventional angiography as the gold standard. The contrast-to-noise (C/N) ratios of both subtracted and nonsubtracted maximum-intensity-projection (MIP) images were calculated.
RESULTS: In the arteries with stenosis of 50% or greater, the sensitivity and specificity of the subtracted MR angiograms were 100% and 96.5%, respectively, not significantly different from the corresponding values in nonsubtracted MRAs (100% and 94.1%, respectively). The C/N ratios of the subtracted images were significantly higher than those of the nonsubtracted images (p<0.001).
CONCLUSION: With this technique, fat suppression can be performed with only a slight increase in the examination time. A lower dose of contrast material can be used in MRA with fat suppression than without it. Subtracted MRA improves the ease of interpretation compared to nonsubtracted MRA.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10741784     DOI: 10.1080/028418500127345136

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  1 in total

Review 1.  Diagnostic performance of computed tomography angiography and contrast-enhanced magnetic resonance angiography in patients with critical limb ischaemia and intermittent claudication: systematic review and meta-analysis.

Authors:  Sjoerd Jens; Mark J W Koelemay; Jim A Reekers; Shandra Bipat
Journal:  Eur Radiol       Date:  2013-06-26       Impact factor: 5.315

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.