Literature DB >> 10739556

Ultra-fast three-dimensional MR perfusion imaging of the entire brain in acute stroke assessment.

S Flacke1, H Urbach, P J Folkers, E Keller, J S van den Brink, F Träber, W Block, J Gieseke, H H Schild.   

Abstract

We sought to evaluate a three-dimensional (3D) whole-brain perfusion technique based on echo-shifting (PRESTO) for its performance in evaluation of acute stroke. Twenty-six patients were scanned within 6 hours after onset of hemispheric symptoms, and the results were compared with results of diffusion-weighted imaging (DWI) and digital subtraction angiography (DSA). The signal-to-noise ratio of the images was 61 +/- 3 pre-contrast and 47 +/- 3 at the bolus peak. Brain coverage on perfusion parameter maps was 95% +/- 2% compared with that displayed on T2-weighted images, with only minor artifacts related to susceptibility at the skull base. Measured regional cerebral blood volume (rCBV) reduction closely correlated to lesion size on initial DWI and to final clinical outcome (P = 0.006), consistent with results previously reported for 2D perfusion methods. Mismatches between DWI and perfusion imaging characterized the total extent of tissue at risk, and the contrast timing correlated with the amount of collateral circulation as shown on DSA. In conclusion, 3D imaging using the PRESTO technique permits high-quality perfusion imaging of the entire brain.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10739556     DOI: 10.1002/(sici)1522-2586(200003)11:3<250::aid-jmri3>3.0.co;2-o

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  4 in total

Review 1.  The optimal use of contrast agents at high field MRI.

Authors:  Siegfried Trattnig; Kathia Pinker; Ahmed Ba-Ssalamah; Iris-Melanie Nöbauer-Huhmann
Journal:  Eur Radiol       Date:  2006-03-01       Impact factor: 5.315

Review 2.  The PRESTO technique for fMRI.

Authors:  P van Gelderen; J H Duyn; N F Ramsey; G Liu; C T W Moonen
Journal:  Neuroimage       Date:  2012-01-08       Impact factor: 6.556

3.  Alteration of cerebral perfusion in patients with idiopathic normal pressure hydrocephalus measured by 3D perfusion weighted magnetic resonance imaging.

Authors:  Christof Walter; F Hertel; E Naumann; M Mörsdorf
Journal:  J Neurol       Date:  2005-07-20       Impact factor: 4.849

4.  Iron-induced susceptibility effect at the globus pallidus causes underestimation of flow and volume on dynamic susceptibility contrast-enhanced MR perfusion images.

Authors:  Kei Yamada; R Gilberto Gonzalez; Leif ØStergaard; Suzanne Komili; Robert M Weisskoff; Bruce R Rosen; Walter J Koroshetz; Tsunehiko Nishimura; A Gregory Sorensen
Journal:  AJNR Am J Neuroradiol       Date:  2002 Jun-Jul       Impact factor: 3.825

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.