Literature DB >> 10739194

Sensing of acetylcholine by a tricomponent-enzyme layered electrode using faradaic impedance spectroscopy, cyclic voltammetry, and microgravimetric quartz crystal microbalance transduction methods.

L Alfonta1, E Katz, I Willner.   

Abstract

A three-enzyme layered assembly on Au electrodes or Au-quartz crystals, consisting of horseradish peroxidase, HRP, choline oxidase, ChO, and acetylcholine esterase, AChE, is used to sense acetylcholine by the HRP-mediated oxidation of 3,3',5,5'-tetramethylbenzidine, TMB (1), by H2O2, and the formation of the insoluble product (2) on the respective transducers. The analyte-substrate, acetylcholine, is hydrolyzed by AChE to choline that is oxidized by ChO and O2 to yield the respective betaine and H2O2. The amounts of generated H2O2 and the resulting insoluble product on the transducers correlate with the concentration of acetylcholine in the samples. The formation of the insoluble product (2) on electrode supports is followed by faradaic impedance spectroscopy that probes the increased interfacial electron-transfer resistance upon the formation of 2, and by cyclic voltammetry that reflects electron-transfer barriers upon the formation of the precipitate. The frequency of the Au-quartz crystal decreases as a result of the accumulation of the insoluble precipitate. The amount of insoluble product formed on the transducers is controlled by the concentration of acetylcholine and by the time interval of biocatalyzed precipitation. The generation of the insoluble product provides a means to amplify the sensing processes. Acetylcholine concentrations corresponding to 1 x 10(-5) M are easily sensed by the different transducers.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10739194     DOI: 10.1021/ac990439d

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  Impedance-based detection of DNA sequences using a silicon transducer with PNA as the probe layer.

Authors:  A Macanovic; C Marquette; C Polychronakos; M F Lawrence
Journal:  Nucleic Acids Res       Date:  2004-01-22       Impact factor: 16.971

2.  Electrochemical immunosensors for antibodies to peanut allergen ara h2 using gold nanoparticle-peptide films.

Authors:  Hongyun Liu; Ruchika Malhotra; Mark W Peczuh; James F Rusling
Journal:  Anal Chem       Date:  2010-07-01       Impact factor: 6.986

3.  Detection of evoked acetylcholine release in mouse brain slices.

Authors:  R Asri; B O'Neill; J C Patel; K A Siletti; M E Rice
Journal:  Analyst       Date:  2016-11-14       Impact factor: 4.616

4.  EQCM immunoassay for phosphorylated acetylcholinesterase as a biomarker for organophosphate exposures based on selective zirconia adsorption and enzyme-catalytic precipitation.

Authors:  Hua Wang; Jun Wang; Daiwon Choi; Zhiwen Tang; Hong Wu; Yuehe Lin
Journal:  Biosens Bioelectron       Date:  2008-12-14       Impact factor: 10.618

Review 5.  Piezoelectric biosensors for organophosphate and carbamate pesticides: a review.

Authors:  Giovanna Marrazza
Journal:  Biosensors (Basel)       Date:  2014-09-09
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.