Radial dose functions for 103Pd, 125I, 169Yb and 192Ir brachytherapy sources: an EGS4 Monte Carlo study.

E Mainegra1, R Capote, E López.   

Abstract

Radial dose functions g(r) in water around 103Pd, 125I, 169Yb and 192Ir brachytherapy sources were estimated by means of the EGS4 simulation system and extensively compared with experimental as well as with theoretical results. The DLC-136/PHOTX cross section library, water molecular form factors, bound Compton scattering and Doppler broadening of the Compton-scattered photon energy were considered in the calculations. Use of the point source approach produces reasonably accurate values of the radial dose function only at distances beyond 0.5 cm for 103Pd sources. It is shown that binding corrections for Compton scattering have a negligible effect on radial dose function for 169Yb and 192Ir seeds and for 103Pd seeds under 5.0 cm from the source centre and for the 125I seed model 6702 under 8.0 cm. Beyond those limits there is an increasing influence of binding corrections on radial dose function for 103Pd and 125I sources. Results in solid water medium underestimate radial dose function for low-energy sources by as much as 6% for 103Pd and 2.5% for 125I already at 2 cm from source centre resulting in a direct underestimation of absolute dose rate values. It was found necessary to consider medium boundaries when comparing results for the radial dose function of 169Yb and 192Ir sources to avoid discrepancies due to the backscattering contribution in the phantom medium. Values of g(r) for all source types studied are presented. Uncertainties lie under 1% within one standard deviation.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10730965     DOI: 10.1088/0031-9155/45/3/309

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Differential dose contributions on total dose distribution of (125)I brachytherapy source.

Authors:  B Camgöz; G Yeğin; M N Kumru
Journal:  Rep Pract Oncol Radiother       Date:  2010-05-26

2.  Evaluation of interpolation methods for TG-43 dosimetric parameters based on comparison with Monte Carlo data for high-energy brachytherapy sources.

Authors:  Ma Carmen Pujades-Claumarchirant; Domingo Granero; Jose Perez-Calatayud; Facundo Ballester; Christopher Melhus; Mark Rivard
Journal:  J Contemp Brachytherapy       Date:  2010-04-01

3.  Local tumor control probability to evaluate an applicator-guided volumetric-modulated arc therapy solution as alternative of 3D brachytherapy for the treatment of the vaginal vault in patients affected by gynecological cancer.

Authors:  Piernicola Pedicini; Lidia Strigari; Rocchina Caivano; Alba Fiorentino; Giorgia Califano; Antonio Nappi; Giuseppina Improta; Giovanni Storto; Mariella Cozzolino; Costanza Chiumento; Vincenzo Fusco; Andrea Vavassori; Marcello Benassi; Roberto Orecchia; Marco Salvatore
Journal:  J Appl Clin Med Phys       Date:  2013-03-04       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.