Double Application of TA-90 B Four-Row AutoSuture(c) Stapling Instrument: A Safe, Effective Method of Staple-line Production Indicated by Follow-up GI Series.

.   

Abstract

BACKGROUND: Controversy continues, concerning the best method of isolating upper and lower gastric pouches in Roux-Y gastric bypass. This paper reports a technique used from August 1991 through May 1996, in which there was a double application of the TA-90 B Four-Row AutoSuture Stapling Instrument to form the proximal gastric pouch. Because of a significant staple-line failure rate historically, many are separating the pouches. However, due to recent reports of gastro-gastric fistula formation when pouch separation is done, a second look has been taken at stapling the division without separation of the pouches.
METHODS: There were 650 patients in this series, and 160 asymptomatic patients 1-4 years postoperatively agreed to have limited upper series.
RESULTS: Only one of this group had staple-line failure. Failures were seen in four of 19 symptomatic patients with dyspepsia or rapid weight regain. Putting these two groups together, our staple-line failure rate has been less than 1% using this technique.
CONCLUSION: Whether stapling in continuity or dividing the stomach, the two methods appear to be equally effective with comparable morbidity. Patients with staple-line failure or gastro-gastric fistulae will ultimately be forced by their symptoms of rapid weight regain and/or peptic ulcer disease and reflux esophagitis to return for follow-up. Asymptomatic patients very rarely have a connection between upper and lower pouches, and routine follow-up upper GI series are not indicated.

Entities:  

Year:  1996        PMID: 10729898     DOI: 10.1381/096089296765556395

Source DB:  PubMed          Journal:  Obes Surg        ISSN: 0960-8923            Impact factor:   4.129


  2 in total

1.  Non-transectional open gastric bypass as the definitive bariatric procedure for 61 patients with BMI of 70 and higher.

Authors:  Gus J Slotman
Journal:  Obes Surg       Date:  2009-10-14       Impact factor: 4.129

2.  A novel narrow profile articulating powered vascular stapler provides superior access and haemostasis equivalent to conventional devices†.

Authors:  Calvin S H Ng; Allan Pickens; Julianne M Siegel; Jeffrey W Clymer; John F Cummings
Journal:  Eur J Cardiothorac Surg       Date:  2015-10-13       Impact factor: 4.191

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.