Non-invasive evaluation of the location, the functional integrity and the oxygen supply of implants: 19F nuclear magnetic resonance imaging of perfluorocarbon-loaded Ba2+-alginate beads.

U Zimmermann1, U Nöth, P Gröhn, A Jork, K Ulrichs, J Lutz, A Haase.   

Abstract

19F nuclear magnetic resonance imaging (MRI) can be used as a non-invasive tool to simultaneously determine the location, the integrity and the oxygen supply of Ba2+-alginate implants. This requires that the beads (implants) are pre-loaded with the perfluorocarbon compound F-44E. Implantation of solid 19F-labelled beads into the peritoneum, below the kidney capsule or into the muscle of Wistar WU rats demonstrated that these beads could be detected by 19F-MRI for up to 18 months after implantation. This indicated that F-44E is not considerably released from the beads during implantation. The signal to noise ratio of liquid-core beads was higher by a factor of 4 than the signal to noise ratio of solid beads, but liquid-core beads were more fragile and also too large for implantation under the kidney capsule and into the intramuscular tissue. Quantitative 2-dimensional 19F-T1 maps (resolution 0.5 x 0.5 mm) could be deduced from 19F-MRI measurements. These T1-maps correlated to the local pO2-values. The partial oxygen pressure estimated in F-44E-loaded Ba2+-alginate beads showed that the oxygen supply inside the beads was very poor when they were implanted below the kidney capsule or into the peritoneal cavity. These low pO2-values obtained for the renal subcapsular site and the peritoneum may explain the failure of previous immunoisolated islet transplantation studies using these locations.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10728581     DOI: 10.3109/10731190009118576

Source DB:  PubMed          Journal:  Artif Cells Blood Substit Immobil Biotechnol        ISSN: 1073-1199


  4 in total

Review 1.  Enhancing clinical islet transplantation through tissue engineering strategies.

Authors:  Jaime A Giraldo; Jessica D Weaver; Cherie L Stabler
Journal:  J Diabetes Sci Technol       Date:  2010-09-01

2.  Simultaneous spatiotemporal tracking and oxygen sensing of transient implants in vivo using hot-spot MRI and machine learning.

Authors:  Virginia Spanoudaki; Joshua C Doloff; Wei Huang; Samuel R Norcross; Shady Farah; Robert Langer; Daniel G Anderson
Journal:  Proc Natl Acad Sci U S A       Date:  2019-02-26       Impact factor: 11.205

3.  Development and Validation of Noninvasive Magnetic Resonance Relaxometry for the In Vivo Assessment of Tissue-Engineered Graft Oxygenation.

Authors:  Samuel A Einstein; Bradley P Weegman; Meri T Firpo; Klearchos K Papas; Michael Garwood
Journal:  Tissue Eng Part C Methods       Date:  2016-11       Impact factor: 3.056

4.  In vivo noninvasive monitoring of dissolved oxygen concentration within an implanted tissue-engineered pancreatic construct.

Authors:  Fernie Goh; Athanassios Sambanis
Journal:  Tissue Eng Part C Methods       Date:  2011-05-25       Impact factor: 3.056

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.