Literature DB >> 10727302

Depth of cutaneous analgesia after application of a eutectic mixture of the local anesthetics lidocaine and prilocaine (EMLA cream).

C F Wahlgren1, H Quiding.   

Abstract

BACKGROUND: EMLA cream, a eutectic mixture of lidocaine and prilocaine, is a topical anesthetic, frequently used to avoid pain during venipuncture and superficial surgery. However, the depth of analgesia needs further exploration.
OBJECTIVE: Our purpose was to investigate the depth of cutaneous analgesia after application of EMLA cream.
METHODS: In a single-blind crossover study, EMLA cream was applied under occlusion to the left thighs of 16 subjects. Eleven had application times of 60 and 120 minutes. Five subjects had application times of 3 to 4 hours. Approximately 10 minutes after removal of the EMLA cream, a skin biopsy punch (diameter 4 mm) was inserted to a depth of 1 mm into the skin and the subject rated the pain intensity on a visual analogue scale. If there was no pain or if pain was assessed as acceptable, a new biopsy punch was inserted at a new site to the depth of 2 mm. In this manner, the insertion depth was gradually increased in steps of 1 mm down to a maximum of 6 mm. No skin specimens were removed.
RESULTS: After 60 and 120 minutes of EMLA application the mean insertion depths with acceptable pain were 2.9 and 4.5 mm (P <.01), respectively. After 3 to 4 hours of application, 6-mm deep insertions were made with acceptable pain in all 5 subjects.
CONCLUSION: Skin biopsy punch insertions in steps of 1 mm appear adequate for assessing the depth of cutaneous analgesia. Biopsy punch insertions with acceptable pain can be made to depths of 1 to 2 mm after 60 minutes, to 2 to 3 mm after 120 minutes, and to 6 mm after 3 to 4 hours of EMLA cream application.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10727302

Source DB:  PubMed          Journal:  J Am Acad Dermatol        ISSN: 0190-9622            Impact factor:   11.527


  17 in total

1.  Availability of a 5% lidocaine patch used prophylactically for venipuncture- or injection-related pain in children.

Authors:  Cheul-Hong Kim; Ji-Uk Yoon; Hyeon-Jung Lee; Sang-Wook Shin; Ji-Young Yoon; Gyeong-Jo Byeon
Journal:  J Anesth       Date:  2012-03-09       Impact factor: 2.078

2.  Anesthesia methods in laser resurfacing.

Authors:  Sergio Gaitan; Ramsey Markus
Journal:  Semin Plast Surg       Date:  2012-08       Impact factor: 2.314

3.  Canadian Urological Association guideline on the care of the normal foreskin and neonatal circumcision in Canadian infants (full version).

Authors:  Sumit Dave; Kourosh Afshar; Luis H Braga; Peter Anderson
Journal:  Can Urol Assoc J       Date:  2017-12-01       Impact factor: 1.862

4.  Coating solid dispersions on microneedles via a molten dip-coating method: development and in vitro evaluation for transdermal delivery of a water-insoluble drug.

Authors:  Yunzhe Ma; Harvinder S Gill
Journal:  J Pharm Sci       Date:  2014-09-11       Impact factor: 3.534

5.  A clinical comparison of topical piroxicam and EMLA cream for pain relief and inflammation in laser hair removal.

Authors:  Semra Akinturk; Ahmet Eroglu
Journal:  Lasers Med Sci       Date:  2008-08-21       Impact factor: 3.161

6.  Effectiveness of Topical Lidocaine-Prilocaine Cream for Pain Control During Femoral Artery Catheterization in Adult Patients: A Prospective Study.

Authors:  Adnan I Qureshi; Muhammad A Saleem; Nishath Naseem; Emrah Aytac; Cetin Kursad Akpinar; Shawn S Wallery
Journal:  J Vasc Interv Neurol       Date:  2018-06

7.  Evaluation of EMLA cream for preventing pain during tattooing of rabbits: changes in physiological, behavioural and facial expression responses.

Authors:  Stephanie C J Keating; Aurelie A Thomas; Paul A Flecknell; Matthew C Leach
Journal:  PLoS One       Date:  2012-09-07       Impact factor: 3.240

8.  Percutaneous dermal drug delivery for local pain control.

Authors:  Sujatha Tadicherla; Brian Berman
Journal:  Ther Clin Risk Manag       Date:  2006-03       Impact factor: 2.423

9.  Review of lidocaine/tetracaine cream as a topical anesthetic for dermatologic laser procedures.

Authors:  Tina Alster
Journal:  Pain Ther       Date:  2013-04-06

10.  Transformation of eutectic emulsion to nanosuspension fabricating with solvent evaporation and ultrasonication technique.

Authors:  Thawatchai Phaechamud; Sarun Tuntarawongsa
Journal:  Int J Nanomedicine       Date:  2016-06-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.