Literature DB >> 10726885

Adhesive strength of autologous fibrin glue.

H Yoshida1, K Hirozane, A Kamiya.   

Abstract

To establish an easy and rapid method for measuring the adhesive strength of fibrin glue and to clarify the factor(s) most affecting the strength, a study was made on the effect of the concentration of plasma components on the strength of cryoprecipitate (Cryo) prepared from a subject's own autologous plasma to be used as fibrin glue. The adhesive strength of the Cryo was measured with various supporting materials instead of animal skin using a tester of tension and compression. The results were as follows: (1) the strength of Cryo applied to ground flat glass (4 cm2) was significantly greater than that applied to clear glass, clear plastic, or smooth and flat wood chips; (2) the adhesive strength of Cryo depended on the concentration of thrombin with the optimal concentration being 50 units/ml; (3) the concentration of CaCl2 did not affect the adhesive strength of Cryo; (4) the adhesive reaction was dependent on the temperature and the adhesive strength more quickly reached a steady state at 37 degrees C than at lower temperature; (5) the adhesive strength was correlated well with the total concentration of fibrinogen and fibronectin. These results indicate that the adhesive strength of Cryo can be easily and quickly evaluated using a tester and ground glass with thrombin at 50 units/ml, and that the adhesive strength of Cryo can be predicted from the total concentration of fibrinogen and fibronectin.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10726885     DOI: 10.1248/bpb.23.313

Source DB:  PubMed          Journal:  Biol Pharm Bull        ISSN: 0918-6158            Impact factor:   2.233


  13 in total

1.  Effect of Fibrin Formulation on Initial Strength of Tendon Repair and Migration of Bone Marrow Stromal Cells in Vitro.

Authors:  Kosuke Uehara; Chunfeng Zhao; Anne Gingery; Andrew R Thoreson; Kai-Nan An; Peter C Amadio
Journal:  J Bone Joint Surg Am       Date:  2015-11-04       Impact factor: 5.284

2.  Quality of thrombin produced from the patient's own plasma using the TPD, a new Thrombin-processing Device.

Authors:  Elisabeth Semple; Trista Madsen; John W Semple
Journal:  J Extra Corpor Technol       Date:  2005-06

3.  Can autologous thrombin with a rest fraction of ethanol be used safely for activation of concentrated autologous platelets applied on nerves?

Authors:  Filip De Somer; Veerle De Brauwer; Maxence Vandekerckhove; Richard Ducatelle; Dirk Uyttendaele; Guido Van Nooten
Journal:  Eur Spine J       Date:  2005-06-17       Impact factor: 3.134

4.  Handheld skin printer: in situ formation of planar biomaterials and tissues.

Authors:  Navid Hakimi; Richard Cheng; Lian Leng; Mohammad Sotoudehfar; Phoenix Qing Ba; Nazihah Bakhtyar; Saeid Amini-Nik; Marc G Jeschke; Axel Günther
Journal:  Lab Chip       Date:  2018-05-15       Impact factor: 6.799

5.  Influence of calcium chloride and aprotinin in the in vivo biological performance of a composite combining biphasic calcium phosphate granules and fibrin sealant.

Authors:  Laurent Le Guehennec; Eric Goyenvalle; Eric Aguado; Paul Pilet; Reiner Spaethe; Guy Daculsi
Journal:  J Mater Sci Mater Med       Date:  2007-03-27       Impact factor: 3.896

6.  Whole blood thrombin: development of a process for intra-operative production of human thrombin.

Authors:  Vijay Kumar; John R Chapman
Journal:  J Extra Corpor Technol       Date:  2007-03

7.  Autologous thrombin: intraoperative production from whole blood.

Authors:  Vijay Kumar; John R Chapman
Journal:  J Extra Corpor Technol       Date:  2008-06

8.  An organosynthetic dynamic heart model with enhanced biomimicry guided by cardiac diffusion tensor imaging.

Authors:  Clara Park; Yiling Fan; Gregor Hager; Hyunwoo Yuk; Manisha Singh; Allison Rojas; Aamir Hameed; Mossab Saeed; Nikolay V Vasilyev; Terry W J Steele; Xuanhe Zhao; Christopher T Nguyen; Ellen T Roche
Journal:  Sci Robot       Date:  2020-01-29

9.  Stability of human thrombin produced from 11 ml of plasma using the thrombin processing device.

Authors:  Vijay Kumar; Trista Madsen; Haihong Zhu; Elisabeth Semple
Journal:  J Extra Corpor Technol       Date:  2005-12

Review 10.  Fibrin glue in ophthalmology.

Authors:  Anita Panda; Sandeep Kumar; Abhiyan Kumar; Raseena Bansal; Shibal Bhartiya
Journal:  Indian J Ophthalmol       Date:  2009 Sep-Oct       Impact factor: 1.848

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.