Literature DB >> 10726817

Biochemical factors influencing measurement of cardiac troponin I in serum.

A Katrukha1, A Bereznikova, V Filatov, T Esakova.   

Abstract

Troponin I (cTnI), a sensitive and reliable marker of damaged cardiac tissue, is now widely used in clinics. But the existence of different cTnI assays with a wide variety of cut-off values and discrepancies between the results of measurements of one and the same sample by different assays is puzzling for clinicians. The most urgent issue at the moment is the development of the international standard, which can be used for the calibration of different assays, thus decreasing between assay biases. But another important item, which should be considered by manufacturers, is the standardisation of the epitopes of the antibodies used for the assay development. The importance of such standardisation originates from the complicated biochemical nature of cTnI. Here we briefly try to analyse the main factors that can influence antigen recognition by different antibodies and formulate principles of antibody selection for assay development.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10726817     DOI: 10.1515/CCLM.1999.159

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  5 in total

1.  How should clinicians interpret cardiac troponin values in patients with ESRD?

Authors:  Nishank Jain; S Susan Hedayati
Journal:  Semin Dial       Date:  2011 Jul-Aug       Impact factor: 3.455

2.  Cardiac troponin I but not cardiac troponin T adheres to polysulfone dialyser membranes in an in vitro haemodialysis model: explanation for lower serum cTnI concentrations following dialysis.

Authors:  David C Gaze; Paul O Collinson
Journal:  Open Heart       Date:  2014-06-12

Review 3.  Cardiac Troponins in Dogs and Cats.

Authors:  R Langhorn; J L Willesen
Journal:  J Vet Intern Med       Date:  2015-12-17       Impact factor: 3.333

4.  Beckman Access versus the Bayer ACS:180 and the Abbott AxSYM cardiac Troponin-I real-time immunoassays: an observational prospective study.

Authors:  Robert H Baevsky; Rajesh K Kapur; Howard A Smithline
Journal:  BMC Emerg Med       Date:  2004-07-13

5.  Evaluation in an emergency department of rapid separator tubes containing thrombin for serum preparation prior to hs-cTnT and CK-MB analyses.

Authors:  Yasemin U Budak; Kagan Huysal; Mehtap Bulut; Murat Polat
Journal:  BMC Clin Pathol       Date:  2013-06-13
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.