An in vitro comparison of two modern apex locators.

R Weiger1, C John, H Geigle, C Löst.   

Abstract

Two apex locators were compared regarding their ability to accurately locate the apical constriction in the presence of various canal fluids at different meter readings. Forty-one root canals were filled with 1% NaOCl, 3% H2O2, and 0.9% NaCl, respectively. Electronic working length (EWL) measurements were recorded with the apex locators Root ZX (meter readings: "Apex", "0.5", and "1") and Apit (meter readings: "Apex" and "3"). The deviation of the EWL from the apical constriction was determined. The proportion of measurements within +/- 0.5 mm of the apical constriction ranged between 0.76 and 0.85 for Root ZX at the meter readings "Apex" and "0.5," regardless of the canal contents. Apit consistently displayed shorter measurement values than Root ZX and reached the highest proportions at the meter reading "Apex": 0.59 (1% NaOCl), 0.61 (3% H2O2), and 0.68 (0.9% NaCl). In the presence of NaOCl, Root ZX provides the more accurate EWL measurements at the meter reading "0.5" and "Apex."

Entities:  

Mesh:

Year:  1999        PMID: 10726548     DOI: 10.1016/S0099-2399(99)80128-9

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  9 in total

1.  Clinical evaluation of Root ZX II electronic apex locator in primary teeth.

Authors:  S Saritha; K S Uloopi; C Vinay; R Chandra Sekhar; V V Rao
Journal:  Eur Arch Paediatr Dent       Date:  2012-02

2.  Comparison of two electronic apex locators on human cadavers.

Authors:  Luca Marigo; Gian Luca Gervasi; Francesco Somma; Giuseppe Squeo; Raffaella Castagnola
Journal:  Clin Oral Investig       Date:  2015-11-04       Impact factor: 3.573

3.  In vitro evaluation of the accuracy of two electronic apex locators.

Authors:  Viresh Chopra; Shibani Grover; S Datta Prasad
Journal:  J Conserv Dent       Date:  2008-04

4.  Comparison of accuracy of two electronic apex locators in the presence of various irrigants: An in vitro study.

Authors:  J Paras Mull; Vinutha Manjunath; Mk Manjunath
Journal:  J Conserv Dent       Date:  2012-04

5.  An in vitro evaluation of the accuracy of four electronic apex locators using stainless-steel and nickel-titanium hand files.

Authors:  Paras Mull Gehlot; Vinutha Manjunath; Mysore Krishnaswamy Manjunath
Journal:  Restor Dent Endod       Date:  2016-01-04

6.  Design and working of "Vasundhara's model for elementary endodontic training": A novel preclinical endodontic model.

Authors:  Vijayaraghavan Siddheswaran; Anvesha Parate; Vasundhara Shivanna
Journal:  J Conserv Dent       Date:  2022-06-13

7.  The effect of file size on the accuracy of the raypex 5 apex locator: an in vitro study.

Authors:  Shiva Sadeghi; Masoomeh Abolghasemi
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2008-05-15

8.  An In Vitro Comparison of Propex II Apex Locator to Standard Radiographic Method.

Authors:  Kalyan Vinayak Chakravarthy Pishipati
Journal:  Iran Endod J       Date:  2013-08-01

9.  An in vivo comparison of accuracy of two electronic apex locators in determining working length using stainless steel and nickel titanium files.

Authors:  Sanjeeb Chaudhary; Archana Gharti; Bhawana Adhikari
Journal:  Clin Cosmet Investig Dent       Date:  2018-05-22