Literature DB >> 10726547

Thermafil retreatment using a new "System B" technique or a solvent.

J F Wolcott1, V T Himel, M L Hicks.   

Abstract

The solid plastic carrier in the Thermafil obturation system must be removed to facilitate retreatment. The purpose of this study was to compare the efficacy and time required to retreat canals obturated with Thermafil with plastic carriers using a new technique based on the System B HeatSource or a solvent. Fifty-two extracted human mandibular premolars with single canals were instrumented and then obturated with Thermafil with plastic carriers. After 2 wk storage at 22 degrees C and 100% humidity, they were randomly divided into 2 groups of 26 teeth each. Group 1 teeth were retreated using chloroform and hand files, whereas teeth in group 2 were retreated with a new technique using the System B HeatSource. The end point of retreatment was defined as complete removal of the plastic carrier. The time required for retreatment was recorded. Then, the apical 5 mm segment of each root was sectioned horizontally at 1 mm intervals and each section digitally imaged. The total area of the canal and the area of the canal occupied by gutta-percha and sealer were measured using NIH image software. Data were analyzed using an unpaired t test. The mean time for retrieval of the plastic carrier was significantly less for the System B technique (1.8 min) than for the solvent technique (3.6 min) (p < 0.001). The difference between the two groups in the amount of filling material (carrier, gutta-percha, and sealer) removed was not significant (p > 0.05).

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10726547     DOI: 10.1016/S0099-2399(99)80127-7

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  4 in total

1.  Efficacy of ultrasonic activation of NaOCl and orange oil in removing filling material from mesial canals of mandibular molars with and without isthmus.

Authors:  Mirela Sangoi Barreto; Ricardo Abreu da Rosa; Manuela Favarin Santini; Bruno Cavalini Cavenago; Marco Antônio Húngaro Duarte; Carlos Alexandre Souza Bier; Marcos Vinícius Reis Só
Journal:  J Appl Oral Sci       Date:  2015-07-21       Impact factor: 2.698

2.  Retreatability of two endodontic sealers, EndoSequence BC Sealer and AH Plus: a micro-computed tomographic comparison.

Authors:  Enrique Oltra; Timothy C Cox; Matthew R LaCourse; James D Johnson; Avina Paranjpe
Journal:  Restor Dent Endod       Date:  2016-12-08

3.  Comparative Evaluation of Efficacy of Protaper Universal Retreatment System, R-Endo System and Hedstrom File in Gutta Percha Removal During Root Canal Retreatment- An In Vitro Study.

Authors:  Aravind T Buranade; Youssef Abdullah Algarni; Adel Saeed N Alobaid; Mohammed Abdul Kader; Suheel Manzoor Baba; Ahamed Babiker Mohamed Ali
Journal:  J Pharm Bioallied Sci       Date:  2022-07-13

4.  Efficacy of Reciproc(®) and Profile(®) Instruments in the Removal of Gutta-Percha from Straight and Curved Root Canals ex Vivo.

Authors:  Karem Marfisi; Montserrat Mercadé; Gianluca Plotino; Tatiana Clavel; Fernando Duran-Sindreu; Miguel Roig
Journal:  J Oral Maxillofac Res       Date:  2015-06-30
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.