A comparison of molar root canal preparation using stainless-steel and nickel-titanium instruments.

L A Carvalho1, I Bonetti, M A Borges.   

Abstract

Fifty-four extracted human mandibular molars were embedded and sectioned at two levels. The reassembled mesial root canals were prepared with stainless-steel hand K-files (Flexofiles) and either Nitiflex or Mity nickel-titanium hand K-files using a push-pull anticurvature filing technique. Each of the three experimental groups contained 36 mesial canals randomly distributed. Superimposed pre- and post-instrumentation cross-sectional root images were magnified using a stereomicroscope and transferred to a computer for measurement and statistical analysis. The direction and extent of canal center movement were evaluated. At the apical level, the groups produced no significant difference of direction of canal center movement. In cervical sections, all groups tended to move in a distolingual direction. The three groups, however, produced no significant difference in the cervical sections in the extent of canal center movement. In apical sections, Nitiflex produced the least canal center movement.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10726526     DOI: 10.1016/S0099-2399(99)80302-1

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  6 in total

1.  Evaluation of the Factors and Treatment Options of Separated Endodontic Files Among Dentists and Undergraduate Students in Riyadh Area.

Authors:  Samah Samir Pedir; Abeer Hashem Mahran; Khaled Beshr; Kusai Baroudi
Journal:  J Clin Diagn Res       Date:  2016-03-01

2.  Comparing the amount of removed dentin thickness in root canal treated primary molar teeth using different instrumentation techniques: in-vitro study using CBCT.

Authors:  Y Ghahramani; N Mohammadi; M Zangooei-Booshehri; S Shirdel
Journal:  Eur Arch Paediatr Dent       Date:  2021-09-07

3.  Canal-centering ability: An endodontic challenge.

Authors:  Deivanayagam Kandaswamy; Nagendrababu Venkateshbabu; Ilango Porkodi; Gali Pradeep
Journal:  J Conserv Dent       Date:  2009-01

4.  Retrieval of a separated nickel-titanium instrument using a modified 18-guage needle and cyanoacrylate glue: a case report.

Authors:  Syed Mukhtar-Un-Nisar Andrabi; Ashok Kumar; Huma Iftekhar; Sharique Alam
Journal:  Restor Dent Endod       Date:  2013-05-28

5.  A Comparison of Canal-centering ability of Two Nickel-Titanium Rotary Systems with Nickel Hand Instrumentation with Stainless Steel Hand Instrumentation in 10 to 25° Curved Canals using Kuttler's Cube.

Authors:  Anupama Swarnkar
Journal:  Int J Clin Pediatr Dent       Date:  2015-02-09

6.  CBCT Assessment of Root Dentine Removal by Gates-Glidden Drills and Two Engine-Driven Root Preparation Systems.

Authors:  Azade Harandi; Fatemeh Mohammadpour Maleki; Ehsan Moudi; Maryam Ehsani; Soraya Khafri
Journal:  Iran Endod J       Date:  2017
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.