Literature DB >> 10725104

Binding properties of a monoclonal antibody directed toward lead-chelate complexes.

M Khosraviani1, R C Blake, A R Pavlov, S C Lorbach, H Yu, J B Delehanty, M W Brechbiel, D A Blake.   

Abstract

A monoclonal antibody (2C12) that recognizes a Pb(II)-cyclohexyldiethylenetriamine pentaacetic acid complex was produced by the injection of BALB/c mice with a Pb(II)-chelate complex covalently coupled to a carrier protein. The ability of purified antibody to interact with a variety of metal-free chelators and metal-chelate complexes was assessed by measuring equilibrium dissociation constants. The antibody bound to metal-free trans-cyclohexyldiethylenetriamine pentaacetic acid (CHXDTPA) with an equilibrium dissociation constant of 2.3 x 10(-)(7) M. Addition of Pb(II) increased the affinity of the antibody for the complex by 25-fold; Pb(II) was the only metal cation (of 15 different di-, tri-, and hexavalent metals tested) that increased the affinity of the antibody for CHXDTPA. The increased affinity was due primarily to an increase in the association rate constant. The antibody also had the ability to interact with ethylenediamine tetraacetic acid (EDTA), diethylenetriamine pentaacetic acid (DTPA), and structurally related derivatives, but with affinities from 50- to 10000-fold less than that determined for CHXDTPA. Addition of metals to EDTA-based chelators reduced the affinity of the antibody for these ligands. However, when DTPA was used as the chelator, addition of Pb(II) increased the affinity of the antibody for the complex by 200-fold. The sensitivity of prototype immunoassays for Pb(II) could be modulated by changing the structure of the immobilized metal-chelate complex and/or the soluble chelator used to complex Pb(II) in the test solution.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10725104     DOI: 10.1021/bc9901548

Source DB:  PubMed          Journal:  Bioconjug Chem        ISSN: 1043-1802            Impact factor:   4.774


  7 in total

1.  Colloidal gold nanoparticle probe-based immunochromatographic assay for the rapid detection of chromium ions in water and serum samples.

Authors:  Xi Liu; Jun-Jian Xiang; Yong Tang; Xiao-Li Zhang; Qiang-Qiang Fu; Jun-Hui Zou; YueHe Lin
Journal:  Anal Chim Acta       Date:  2012-07-07       Impact factor: 6.558

Review 2.  A review on nanomaterial-based electrochemical, optical, photoacoustic and magnetoelastic methods for determination of uranyl cation.

Authors:  Leila Farzin; Mojtaba Shamsipur; Shahab Sheibani; Leila Samandari; Zahra Hatami
Journal:  Mikrochim Acta       Date:  2019-04-16       Impact factor: 5.833

3.  Electrospray ionization-ion mobility spectrometry identified monoclonal antibodies that bind exclusively to either the monomeric or a dimeric form of prostate specific antigen.

Authors:  Robert C Blake; Diane A Blake
Journal:  Anal Chem       Date:  2012-07-26       Impact factor: 6.986

4.  Immunoassay Methods and their Applications in Pharmaceutical Analysis: Basic Methodology and Recent Advances.

Authors:  Ibrahim A Darwish
Journal:  Int J Biomed Sci       Date:  2006-09

5.  Using Monoclonal Antibody to Determine Lead Ions with a Localized Surface Plasmon Resonance Fiber-optic Biosensor.

Authors:  Tsao-Jen Lin; Mon-Fu Chung
Journal:  Sensors (Basel)       Date:  2008-01-25       Impact factor: 3.576

6.  Exploring the dynamic range of the kinetic exclusion assay in characterizing antigen-antibody interactions.

Authors:  Christine Bee; Yasmina N Abdiche; Donna M Stone; Sierra Collier; Kevin C Lindquist; Alanna C Pinkerton; Jaume Pons; Arvind Rajpal
Journal:  PLoS One       Date:  2012-04-30       Impact factor: 3.240

7.  Rapid and highly sensitive detection of lead ions in drinking water based on a strip immunosensor.

Authors:  Hua Kuang; Changrui Xing; Changlong Hao; Liqiang Liu; Libing Wang; Chuanlai Xu
Journal:  Sensors (Basel)       Date:  2013-03-28       Impact factor: 3.576

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.