Literature DB >> 10723875

Selection of measurement frequencies for optimal extraction of tissue impedance model parameters.

S Kun1, R A Peura.   

Abstract

The results are presented of a study performed to determine the measurement frequencies that provide optimal extraction of tissue impedance model parameters from in vivo measured electrical impedance spectra. Measurement frequency sets that are logarithmic and quasi-linear, and frequency sets that produce angularly equidistant points on the Nyquist loci are used to test the parametric fitting algorithm that calculates R0, R infinity, alpha and tau tissue parameters from complex impedance spectra. Simulated data, calculated in the presence of < or = 5% measurement noise, and in vivo experiments indicate that the quality of the fitted parameters depends upon the selection of measurement frequencies. The results show that, if measurements are performed with a system that has a realistic measurement bandwidth, then, for the best estimation of: R0, the measurement frequencies should include the decade from 100 Hz-1 kHz; R infinity, the algorithm should not include frequencies under 1 kHz; alpha and tau, the measurement frequencies should be equidistantly spaced on the Nyquist locus.

Mesh:

Year:  1999        PMID: 10723875     DOI: 10.1007/bf02513370

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  7 in total

1.  Real-time extraction of tissue impedance model parameters for electrical impedance spectrometer.

Authors:  S Kun; B Ristic; R A Peura; R M Dunn
Journal:  Med Biol Eng Comput       Date:  1999-07       Impact factor: 2.602

2.  Parametric modelling for electrical impedance spectroscopy system.

Authors:  L Lu; L Hamzaoui; B H Brown; B Rigaud; R H Smallwood; D C Barber; J P Morucci
Journal:  Med Biol Eng Comput       Date:  1996-03       Impact factor: 2.602

3.  Deconvolved electrical impedance spectra track distinct cell morphology changes.

Authors:  D A McRae; M A Esrick
Journal:  IEEE Trans Biomed Eng       Date:  1996-06       Impact factor: 4.538

4.  In vitro tissue characterization and modelling using electrical impedance measurements in the 100 Hz-10 MHz frequency range.

Authors:  B Rigaud; L Hamzaoui; M R Frikha; N Chauveau; J P Morucci
Journal:  Physiol Meas       Date:  1995-08       Impact factor: 2.833

5.  Tissue impedance spectra and the appropriate frequencies for EIT.

Authors:  M Osypka; E Gersing
Journal:  Physiol Meas       Date:  1995-08       Impact factor: 2.833

Review 6.  Methods of complex impedance measurements in biologic tissue.

Authors:  J J Ackmann; M A Seitz
Journal:  Crit Rev Biomed Eng       Date:  1984

7.  Changes in electrical impedance of skeletal muscle measured during hyperthermia.

Authors:  D A McRae; M A Esrick
Journal:  Int J Hyperthermia       Date:  1993 Mar-Apr       Impact factor: 3.914

  7 in total
  3 in total

1.  In silico validation procedure for cell volume fraction estimation through dielectric spectroscopy.

Authors:  Fabrizio Frezza; Fabio Mangini; Marco Muzi; Endri Stoja
Journal:  J Biol Phys       Date:  2015-01-10       Impact factor: 1.365

Review 2.  Gastrointestinal ischemia monitoring through impedance spectroscopy as a tool for the management of the critically ill.

Authors:  Nohra E Beltran; Emilio Sacristan
Journal:  Exp Biol Med (Maywood)       Date:  2015-02-23

3.  Measuring lower leg swelling: optimum frequency for impedance method.

Authors:  A Seo; M Rys; S Konz
Journal:  Med Biol Eng Comput       Date:  2001-03       Impact factor: 3.079

  3 in total