[Interventional catheter treatment of bypass graft stenosis: comparison of intracoronary stent implantation and balloon angioplasty].

U E Heidland1, M P Heintzen, D Schoppmann, C J Michel, B E Strauer.   

Abstract

BACKGROUND AND
OBJECTIVE: Balloon angioplasty of a stenosed bypass graft has a much higher risk of recurrent stenosis than dilatation of a stenosed native coronary artery. Intracoronary stent implantation has established itself as the better treatment of native coronary artery stenosis than conventional balloon angioplasty. However, there is still uncertainty whether intracoronary stent implantation in stenosed bypass vessels gives better long-term results than conventional balloon angioplasty. PATIENTS AND METHODS: Results were retrospectively analyzed of unrandomized 224 primarily successful interventions--122 balloon dilatations and 102 stent implantations--performed between January 1996 and June 1998 on stenosed coronary bypass grafts, re-examined by coronary angiography an average of 6 months later. All but 11 patients were on combined aspirin and ticlopidine antiplatelet aggregation treatment.
RESULTS: There was a significantly lower 6-month restenosis rate (30.4%) after stent implantation than after balloon dilatation (51.6%). The re-intervention rate was also significantly lower after stent implantation.
CONCLUSION: These data suggest that stent implantation of stenosed coronary bypass grafts under cover of platelet-aggregation inhibition with aspirin and ticlopidine provides a lower restenosis and thus higher revascularization rate than conventional balloon dilatation.

Entities:  

Mesh:

Year:  2000        PMID: 10723454     DOI: 10.1055/s-2007-1024050

Source DB:  PubMed          Journal:  Dtsch Med Wochenschr        ISSN: 0012-0472            Impact factor:   0.628


  1 in total

1.  Risk factors for the development of restenosis following stent implantation of venous bypass grafts.

Authors:  U E Heidland; M P Heintzen; C J Michel; B E Strauer
Journal:  Heart       Date:  2001-03       Impact factor: 5.994

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.