Literature DB >> 10722149

AC voltammetric carbon paste-based enzyme immunosensors.

C Fernández-Sánchez1, M B González-García, A Costa-García.   

Abstract

Carbon paste electrodes, previously anodised in a basic media, are the basis for the development of a new voltammetric immunosensor device. Passive adsorption of the appropriate immunochemical reagent was performed onto the electrode surface. Alkaline Phosphatase labelled immunoglobulin was the tracer used in this work, 3-indoxyl phosphate being a very suitable enzymatic substrate for the electrochemical detection of the corresponding affinity reaction. The hydrolysis of this molecule generates indigo dimmer. This product was detected by alternating current voltammetry taking advantage of the adsorptive and inherent electrodic properties that it exhibits. The same electrochemical anodisation was used at the end of one assay to remove the entire protein layer attached to the carbon paste surface, allowing the formation of a new sensing phase and the use of the same support in several consecutive experiments. The methodology was applied to the design of two different immunoassays for the determination of human IgG. Good reproducibility of the electrodic signal and a limit of detection around 10(-10) M were achieved.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10722149     DOI: 10.1016/s0956-5663(99)00065-2

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

1.  Removal of Non-Specifically Bound Proteins Using Rayleigh Waves Generated on ST-Quartz Substrates.

Authors:  Mandek Richardson; Pradipta K Das; Samuel Morrill; Kamlesh J Suthar; Subramanian K R S Sankaranarayanan; Venkat R Bhethanabotla
Journal:  Sensors (Basel)       Date:  2022-05-28       Impact factor: 3.847

Review 2.  Biosensing technologies for Mycobacterium tuberculosis detection: status and new developments.

Authors:  Lixia Zhou; Xiaoxiao He; Dinggeng He; Kemin Wang; Dilan Qin
Journal:  Clin Dev Immunol       Date:  2011-03-16

3.  Immunoglobulin G Determination in Human Serum and Milk Using an Immunosensor of New Conception Fitted with an Enzyme Probe as Transducer.

Authors:  Luigi Campanella; Dalina Lelo; Elisabetta Martini; Mauro Tomassetti
Journal:  Sensors (Basel)       Date:  2008-10-28       Impact factor: 3.576

4.  Heterogeneous electrochemical immunoassay of hippuric acid on the electrodeposited organic films.

Authors:  Young-Bong Choi; Nam-Hyuk Kim; Seung-Hoi Kim; Gun-Sik Tae; Hyug-Han Kim
Journal:  Sensors (Basel)       Date:  2014-10-13       Impact factor: 3.576

  4 in total