Literature DB >> 10722097

Sheath liquid effects in capillary high-performance liquid chromatography-electrospray mass spectrometry of oligonucleotides.

C G Huber1, A Krajete.   

Abstract

Fused-silica capillary columns of 200 microm inner diameter were packed with micropellicular, octadecylated, 2.3 microm poly(styrene-divinylbenzene) particles and applied to the separation of oligonucleotides by ion-pair reversed-phase high-performance liquid chromatography. Oligonucleotides were eluted at 50 degrees C with gradients of 3-13% acetonitrile in 50 mM triethylammonium bicarbonate. Addition of sheath liquid to the column effluent allowed the detection of oligonucleotides by electrospray ionization mass spectrometry using full-scan data acquisition with a detectability comparable to that obtained with UV detection. The signal-to-noise ratios with different sheath liquids increased in the order isopropanol<methanol<acetonitrile. The incorporation of volatile acids or bases such as triethylamine or hexafluoroisopropanol into the sheath liquid was found to influence the charge state distribution of oligonucleotides longer than 20 nucleotide units whereas no significant effect was observed with shorter oligonucleotides. Organic acids and bases in the sheath liquid generally deteriorated the signal-to-noise ratios in the chromatograms and mass spectra mainly because of increased background noise. Only a few charge states were observed in the mass spectra of oligonucleotides because of charge state reduction due to the presence of carbonic acid in the eluent. With triethylammonium hydrogencarbonate as chromatographic eluent and acetonitrile as sheath liquid, very few cation adducts of oligonucleotides were observed in the mass spectra. However, the presence of small amounts of monopotassium adducts enabled the calculation of the charge state of multiply charged ions. With acetonitrile as sheath liquid, 710 amol of a 16-mer oligonucleotide were detected using selected ion monitoring data acquisition with a signal-to-noise ratio of 3:1. Finally, capillary ion-pair reversed-phase high-performance liquid chromatography-electrospray ionization mass spectrometry was applied to the separation and characterization of heterooligonucleotide primers.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10722097     DOI: 10.1016/s0021-9673(99)00953-x

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  6 in total

1.  Re-sequencing of multiple single nucleotide polymorphisms by liquid chromatography-electrospray ionization mass spectrometry.

Authors:  H Oberacher; P J Oefner; G Hölzl; A Premstaller; K Davis; C G Huber
Journal:  Nucleic Acids Res       Date:  2002-07-15       Impact factor: 16.971

2.  Enhancing the response of alkyl methylphosphonic acids in negative electrospray ionization liquid chromatography tandem mass spectrometry by post-column addition of organic solvents.

Authors:  Douglas B Mawhinney; Rayman D Stanelle; Elizabeth I Hamelin; Robert J Kobelski
Journal:  J Am Soc Mass Spectrom       Date:  2007-07-29       Impact factor: 3.109

3.  Optimized suppression of adducts in polymerase chain reaction products for semi-quantitative SNP genotyping by liquid chromatography-mass spectrometry.

Authors:  Herbert Oberacher; Walther Parson; Georg Hölzl; Peter J Oefner; Christian G Huber
Journal:  J Am Soc Mass Spectrom       Date:  2004-12       Impact factor: 3.109

4.  Favorable effects of weak acids on negative-ion electrospray ionization mass spectrometry.

Authors:  Zengru Wu; Wenqing Gao; Mitch A Phelps; Di Wu; Duane D Miller; James T Dalton
Journal:  Anal Chem       Date:  2004-02-01       Impact factor: 6.986

5.  Development of a 'clickable' non-natural nucleotide to visualize the replication of non-instructional DNA lesions.

Authors:  Edward A Motea; Irene Lee; Anthony J Berdis
Journal:  Nucleic Acids Res       Date:  2011-11-15       Impact factor: 16.971

Review 6.  Analysis of Nucleosides and Nucleotides in Plants: An Update on Sample Preparation and LC-MS Techniques.

Authors:  Henryk Straube; Claus-Peter Witte; Marco Herde
Journal:  Cells       Date:  2021-03-20       Impact factor: 6.600

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.