Literature DB >> 10722057

Determination of N-acetylcysteine in human plasma by liquid chromatography coupled to tandem mass spectrometry.

C Celma1, J A Allué, J Pruñonosa, C Peraire, R Obach.   

Abstract

An analytical method for the determination of total N-acetylcysteine in human plasma has been developed, validated and applied to the analysis of samples from a phase I clinical trial. The analytical method consists of plasma digestion with dithiothreitol in order to reduce all the oxidized forms of N-acetylcysteine, and extraction with ethyl acetate followed by determination of levels by an LC-MS-MS method. The intra- and inter-assay precision and accuracy of this technique were good and the limit of quantitation was 50 ng/ml of plasma. The concentration working range was established between 50 ng/ml and 1000 ng/ml. This method has been used in the analysis of approximately 800 human plasma samples from a clinical study with 24 volunteers; the precision of the quality controls was in the range 8.7 to 13.4% and the accuracy was in the range -5.9 to 8.5%, expressed as the RSD and the relative error, respectively.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10722057     DOI: 10.1016/s0021-9673(99)01078-x

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  1 in total

1.  Flow injection spectrophotometric determination of N-acetyl-L-cysteine as a complex with palladium(II).

Authors:  Josipa Giljanović; Mia Brkljača; Ante Prkić
Journal:  Molecules       Date:  2011-08-25       Impact factor: 4.411

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.