Literature DB >> 10721745

Coatings on zirconia for medical applications.

M Ferraris1, E Verné, P Appendino, C Moisescu, A Krajewski, A Ravaglioli, A Piancastelli.   

Abstract

In order to combine the mechanical properties of a high-strength inert ceramic (yttria-stabilised zirconia, ZrO2-3%Y2O3, defined as zirconia in the text) with the specific properties of bioactive materials, some zirconia samples were coated by two bioactive phosphosilicate glasses and glass-ceramics: RKKP and AP40. Coatings of about 200-300 microm thickness were prepared by a simple and low-cost firing method. They were characterised by optical and scanning electron microscopy (SEM) and compositional analysis (EDS). The adhesion of the coatings on zirconia was tested by shear tests. Vickers indentations at the coating/zirconia interface were performed in order to observe the crack propagation path. The reactivity of glasses and glass-ceramics coatings towards a simulated body fluid (SBF), having the same ion concentration as that of human plasma, was evaluated and compared to that of the bulk glass and glass-ceramics, by examining the morphology of the reaction layer formed on the surface of the coated zirconia after one month of soaking in the SBF at 37 degrees C.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10721745     DOI: 10.1016/s0142-9612(99)00209-4

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  7 in total

Review 1.  Adhesion/cementation to zirconia and other non-silicate ceramics: where are we now?

Authors:  Jeffrey Y Thompson; Brian R Stoner; Jeffrey R Piascik; Robert Smith
Journal:  Dent Mater       Date:  2010-11-20       Impact factor: 5.304

2.  Bioactive and thermally compatible glass coating on zirconia dental implants.

Authors:  A Kirsten; A Hausmann; M Weber; J Fischer; H Fischer
Journal:  J Dent Res       Date:  2014-11-24       Impact factor: 6.116

3.  The effect of alumina and aluminium nitride coating by reactive magnetron sputtering on the resin bond strength to zirconia core.

Authors:  Tolga Külünk; Safak Külünk; Seniha Baba; Ozgür Oztürk; Sengül Danişman; Soner Savaş
Journal:  J Adv Prosthodont       Date:  2013-11-28       Impact factor: 1.904

4.  Enhanced Hydrophilicity and Biocompatibility of Dental Zirconia Ceramics by Oxygen Plasma Treatment.

Authors:  Ching-Chou Wu; Chung-Kai Wei; Chia-Che Ho; Shinn-Jyh Ding
Journal:  Materials (Basel)       Date:  2015-02-16       Impact factor: 3.623

5.  Effects of carbon and nitrogen plasma immersion ion implantation on bioactivity of zirconia.

Authors:  Shuqin Guo; Na Liu; Ke Liu; Ying Li; Wei Zhang; Biao Zhu; Bin Gu; Ning Wen
Journal:  RSC Adv       Date:  2020-09-30       Impact factor: 4.036

6.  Effect of Different Surface Treatments and Pressure Conditions on Shear Bond Strength of Zirconia Ceramic to Composite Resin.

Authors:  Sattar Kabiri; Ammar Neshati; Bita Rohani
Journal:  Front Dent       Date:  2021-07-23

7.  Effect of Surface Treatment on Shear Bond Strength between Resin Cement and Ce-TZP/Al2O3.

Authors:  Jong-Eun Kim; Jee-Hwan Kim; June-Sung Shim; Byoung-Duck Roh; Yooseok Shin
Journal:  Biomed Res Int       Date:  2016-06-13       Impact factor: 3.411

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.