Literature DB >> 10721622

A micropower dry-electrode ECG preamplifier.

M J Burke1, D T Gleeson.   

Abstract

This paper describes the development of a very low-power preamplifier intended for use in pasteless-electrode recording of the human electrocardiogram. The expected input signal range is 100 microV-10 mV from a lead-II electrode configuration. The amplifier provides a gain of 43 dB in a 3-dB bandwidth of 0.05 Hz-2 kHz with a defined high input impedance of 75 M omega. It uses a driven common electrode to enhance rejection of common-mode interfering signals, including low-frequency motion artifact, achieving a common-mode rejection ratio (CMRR) of better than 80 dB over its entire bandwidth. The gain and phase characteristics meet the recommendations of the American Heart Association, ensuring low distortion of the output ECG signal and making it suitable for clinical monitoring. The amplifier has a power consumption of 30 microW operating from a 3.3-V battery and is intended for use in small, lightweight, portable electrocardiographic equipment and heart-rate monitoring instrumentation.

Entities:  

Mesh:

Year:  2000        PMID: 10721622     DOI: 10.1109/10.821734

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  9 in total

1.  Two-electrode low supply voltage electrocardiogram signal amplifier.

Authors:  D Dobrev
Journal:  Med Biol Eng Comput       Date:  2004-03       Impact factor: 2.602

2.  Reusable electrical activity of the heart monitoring patch for mobile/ubiquitous healthcare.

Authors:  Jeong-Whan Lee; Kang-Hwi Lee; Young-Jae Lee; Lee-Yon Hong; Dong-Jun Kim; Kyeong-Seop Kim; Bongsoo Lee; Myoungho Lee
Journal:  J Med Syst       Date:  2009-02       Impact factor: 4.460

3.  Effect of combined movement and heart rate monitor placement on physical activity estimates during treadmill locomotion and free-living.

Authors:  Søren Brage; Niels Brage; Ulf Ekelund; Jian'an Luan; Paul W Franks; Karsten Froberg; Nicholas J Wareham
Journal:  Eur J Appl Physiol       Date:  2005-12-13       Impact factor: 3.078

4.  A power-efficient bio-potential acquisition device with DS-MDE sensors for long-term healthcare monitoring applications.

Authors:  Chia-Lin Chang; Chih-Wei Chang; Hong-Yi Huang; Chen-Ming Hsu; Chia-Hsuan Huang; Jin-Chern Chiou; Ching-Hsing Luo
Journal:  Sensors (Basel)       Date:  2010-05-11       Impact factor: 3.576

5.  Properties of screen printed electrocardiography smartware electrodes investigated in an electro-chemical cell.

Authors:  Linda Rattfält; Fredrik Björefors; David Nilsson; Xin Wang; Petronella Norberg; Per Ask
Journal:  Biomed Eng Online       Date:  2013-07-05       Impact factor: 2.819

6.  An Electronic System for the Contactless Reading of ECG Signals.

Authors:  Francesca Romana Parente; Marco Santonico; Alessandro Zompanti; Mario Benassai; Giuseppe Ferri; Arnaldo D'Amico; Giorgio Pennazza
Journal:  Sensors (Basel)       Date:  2017-10-28       Impact factor: 3.576

Review 7.  Dry Electrodes for Human Bioelectrical Signal Monitoring.

Authors:  Yulin Fu; Jingjing Zhao; Ying Dong; Xiaohao Wang
Journal:  Sensors (Basel)       Date:  2020-06-29       Impact factor: 3.576

8.  Development and Test of a Portable ECG Device with Dry Capacitive Electrodes and Driven Right Leg Circuit.

Authors:  Alessandro Zompanti; Anna Sabatini; Simone Grasso; Giorgio Pennazza; Giuseppe Ferri; Gianluca Barile; Massimo Chello; Mario Lusini; Marco Santonico
Journal:  Sensors (Basel)       Date:  2021-04-15       Impact factor: 3.576

9.  Advanced e-Call Support Based on Non-Intrusive Driver Condition Monitoring for Connected and Autonomous Vehicles.

Authors:  Marius Minea; Cătălin Marian Dumitrescu; Ilona Mădălina Costea
Journal:  Sensors (Basel)       Date:  2021-12-10       Impact factor: 3.576

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.