Literature DB >> 10718233

Chemical protective clothing; a study into the ability of staff to perform lifesaving procedures.

M J Coates1, A S Jundi, M R James.   

Abstract

OBJECTIVE: To investigate the ability of medical and nursing staff to perform certain tasks while wearing a chemical protection suit with a respirator. Tasks chosen were those that would be required before decontamination.
METHODS: Ten experienced accident and emergency doctors (middle grade and consultants) and 10 nurses were asked to perform certain tasks that were judged to be life saving, relevant to triage, or necessary to confirm death, on an advanced life support manikin, while wearing a TST-Sweden chemical protection suit. The operators were objectively assessed by one of the authors for achieving each task, then asked to make a subjective assessment of the difficulty experienced.
RESULTS: Medical staff were asked to ventilate the manikin using a bag-valve-mask, intubate within 30 seconds, apply monitor electrodes and cables and check cardiac rhythm, apply gel pads and defibrillate safely, and finally, fold the cruciform triage card to show "RED", and attach it to the manikin. All the doctors completed these tasks, except for one, who could only intubate the manikin after several attempts. Nursing staff were asked to open and apply an oxygen mask, adjust oxygen flow, size and insert an oropharyngeal airway, ventilate the manikin using a bag-valve-mask, apply a pressure bandage to a limb, and fold the cruciform triage card to show "YELLOW", and attach it to the manikin. All the nurses completed these tasks. Operators reported varying degrees of difficulty, the most difficult tasks were those requiring fine movements or delicate control. Generally, operators found the butyl rubber gloves cumbersome. Communication difficulties were frequently reported. Although only intubation was formally timed, tasks were perceived to take longer. Some operators found the suits too warm and uncomfortable.
CONCLUSION: Should the need arise, the TST-Sweden chemical protection suits would enable experienced doctors and nurses to perform lifesaving measures effectively, without significant impairment to their skills. Tasks would be easier to accomplish with better fitting gloves.

Entities:  

Mesh:

Year:  2000        PMID: 10718233      PMCID: PMC1725348          DOI: 10.1136/emj.17.2.115

Source DB:  PubMed          Journal:  J Accid Emerg Med        ISSN: 1351-0622


  8 in total

1.  Speech intelligibility test methodology applied to powered air-purifying respirators used in healthcare.

Authors:  Susan Xu; Jeremy Simons; Patrick Yorio; Dana Rottach; Ziqing Zhuang; Lewis Radonovich
Journal:  J Occup Environ Hyg       Date:  2020-12-07       Impact factor: 2.155

2.  Personal protective equipment for preventing highly infectious diseases due to exposure to contaminated body fluids in healthcare staff.

Authors:  Jos H Verbeek; Blair Rajamaki; Sharea Ijaz; Christina Tikka; Jani H Ruotsalainen; Michael B Edmond; Riitta Sauni; F Selcen Kilinc Balci
Journal:  Cochrane Database Syst Rev       Date:  2019-07-01

3.  Chest Compression With Personal Protective Equipment During Cardiopulmonary Resuscitation: A Randomized Crossover Simulation Study.

Authors:  Jie Chen; Kai-Zhi Lu; Bin Yi; Yan Chen
Journal:  Medicine (Baltimore)       Date:  2016-04       Impact factor: 1.889

4.  Personal protective equipment for preventing highly infectious diseases due to exposure to contaminated body fluids in healthcare staff.

Authors:  Jos H Verbeek; Blair Rajamaki; Sharea Ijaz; Riitta Sauni; Elaine Toomey; Bronagh Blackwood; Christina Tikka; Jani H Ruotsalainen; F Selcen Kilinc Balci
Journal:  Cochrane Database Syst Rev       Date:  2020-04-15

5.  Intubation performance using different laryngoscopes while wearing chemical protective equipment: a manikin study.

Authors:  H Schröder; N Zoremba; R Rossaint; K Deusser; C Stoppe; M Coburn; A Rieg; G Schälte
Journal:  BMJ Open       Date:  2016-03-15       Impact factor: 2.692

6.  Human Factor Considerations in Using Personal Protective Equipment in the COVID-19 Pandemic Context: Binational Survey Study.

Authors:  Avi Parush; Oren Wacht; Ricardo Gomes; Amit Frenkel
Journal:  J Med Internet Res       Date:  2020-06-17       Impact factor: 5.428

Review 7.  Evaluation of the rationale for concurrent use of N95 filtering facepiece respirators with loose-fitting powered air-purifying respirators during aerosol-generating medical procedures.

Authors:  Raymond J Roberge
Journal:  Am J Infect Control       Date:  2008-03       Impact factor: 2.918

8.  B95: a new respirator for health care personnel.

Authors:  Megan E Gosch; Ronald E Shaffer; Aaron E Eagan; Raymond J Roberge; Victoria J Davey; Lewis J Radonovich
Journal:  Am J Infect Control       Date:  2013-05-29       Impact factor: 2.918

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.