Literature DB >> 10714833

Estimation of cardiac preload changes by systolic pressure variation in pigs undergoing pneumoperitoneum.

J P Tournadre1, B Allaouchiche, V Cayrel, L Mathon, D Chassard.   

Abstract

BACKGROUND: Variations in systolic pressure arterial waveform (SPV) and its component have been shown to be a reasonable indicator of left ventricular preload. Creation of a pneumoperitoneum (PMOP) by insufflation of CO2 increases intrathoracic pressure, leading to overestimation of preload as assessed by pressure methods. The purpose of this study was to compare SPV with other standard methods in anaesthetized pigs.
METHODS: We measured SPV and its DeltaDown component (deltaDown), pulmonary artery occlusion pressure (PAOP) and left ventricular short-axis cross-sectional area using transthoracic echocardiography (TTE) in 7 pigs, at baseline, after 12 mmHg PMOP and after an intravascular load with 10 ml/kg hydroxylethylstarch (HES).
RESULTS: PMOP increased SPV from 12.9+/-4.9 to 16.9+/-5.5 mmHg (P<0.05) and decreased pulmonary compliance, with no change in PAOP or end-diastolic area assesssed by TTE. Intravascular volume loading significantly decreased SPV from 16.9+/-5.5 to 11.2+/-4.9 mmHg and deltaDown from 9.9+/-7.1 to 5.2+/-4.5 (P<0.05), and increased PAOP and end-diastolic area. Significant correlation between changes in deltaDown and EDA was noted following HES (r=0.78, P<0.05).
CONCLUSION: In anaesthetized pigs, the creation of a PMOP alters SPV, likely by decreasing lung compliance. Once PMOP is established, changes in cardiac preload could be estimated by SPV analysis.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10714833     DOI: 10.1034/j.1399-6576.2000.440303.x

Source DB:  PubMed          Journal:  Acta Anaesthesiol Scand        ISSN: 0001-5172            Impact factor:   2.105


  4 in total

1.  Comparison of ability of pulse pressure variation to predict fluid responsiveness in prone and supine position: an observational study.

Authors:  Achmet Ali; Taner Abdullah; Pulat Akin Sabanci; Lerzan Dogan; Mukadder Orhan-Sungur; Ibrahim Ozkan Akinci
Journal:  J Clin Monit Comput       Date:  2018-08-16       Impact factor: 2.502

2.  Pneumoperitoneum affects stroke volume variation in humans.

Authors:  Zen'ichiro Wajima; Toshiya Shiga; Kazuyuki Imanaga
Journal:  J Anesth       Date:  2014-12-30       Impact factor: 2.078

3.  Stroke volume variation to guide fluid therapy: is it suitable for high-risk surgical patients? A terminated randomized controlled trial.

Authors:  Ib Jammer; Mari Tuovila; Atle Ulvik
Journal:  Perioper Med (Lond)       Date:  2015-07-22

4.  Influence of tidal volume on pulse pressure variation and stroke volume variation during experimental intra-abdominal hypertension.

Authors:  F Díaz; B Erranz; A Donoso; T Salomon; Pablo Cruces
Journal:  BMC Anesthesiol       Date:  2015-09-22       Impact factor: 2.217

  4 in total