Literature DB >> 10709472

Three-dimensional guidance system for implant insertion: Part II. Dual axes table--problem solving.

L A Weinberg, B Kruger.   

Abstract

The three-dimensional guidance system for implant insertion is a technique for placing a radiopaque vertical orientation pin over the crest of the alveolar ridge on the stone cast during fabrication of the radiographic guide. The cross-sectional and panoramic reformatted images were reproduced on a Polaroid or 35-mm print. The true vertical orientation pin facilitates (1) identification and the exact planned location of each implant in the reformatted images of the CT scan, (2) establishment of the internal starting point for the osteotomy on a photographic print, (3) optimum implant orientation, and (4) measurement of the angulation between the true vertical orientation line and optimum implant orientation. With the aid of a newly developed dual-axes base and transfer of the internal starting point of each implant to the stone cast, the buccolingual and mesiodistal implant inclinations for each implant were transferred to a surgical guide in the form of surgical steel drill guide tubes. The resulting pilot osteotomy transfers to the alveolar bone the exact starting point and the buccolingual and mesiodistal inclination for each implant. The technique provides a three-dimensional guidance system for implant insertion that is extremely accurate and yet practical.

Entities:  

Mesh:

Year:  1999        PMID: 10709472     DOI: 10.1097/00008505-199903000-00007

Source DB:  PubMed          Journal:  Implant Dent        ISSN: 1056-6163            Impact factor:   2.454


  2 in total

1.  In-vitro study on the accuracy of a simple-design CT-guided stent for dental implants.

Authors:  Young-June Huh; Bo-Ram Choi; Kyung-Hoe Huh; Won-Jin Yi; Min-Suk Heo; Sam-Sun Lee; Soon-Chul Choi
Journal:  Imaging Sci Dent       Date:  2012-09-21

2.  A novel surgical template design in staged dental implant rehabilitations.

Authors:  Michael Patras; William Martin; Nikitas Sykaras
Journal:  J Oral Maxillofac Res       Date:  2012-07-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.