Literature DB >> 10709237

Basket catheter localization of the origin of atrial tachycardia with atypical morphology after atrial flutter ablation.

E Rodriguez1, D Callans, B Kantharia, C Gottlieb, F E Marchlinski.   

Abstract

Atrial activation from a site in the low lateral right atrium will typically proceed in a superior direction. We present a case of a low lateral right atrial tachycardia with a surface electrocardiographic P wave morphology that appeared to have an inferiorly directed axis. The tachycardia occurred 2 years after successful atrial flutter ablation. The use of a multipolar basket catheter allowed confirmation of the focal origin of the tachycardia, permitted its rapid localization, facilitated catheter ablation, and provided clues to atrial activation that helped describe the appearance of the P wave.

Entities:  

Mesh:

Year:  2000        PMID: 10709237     DOI: 10.1111/j.1540-8159.2000.tb00811.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  1 in total

1.  Low right atrial tachycardia with positive P waves in the inferior leads: explanation by electroanatomical mapping.

Authors:  Arash Arya; Hans Kottkamp; Christopher Piorkowski; Gerhard Hindricks
Journal:  J Interv Card Electrophysiol       Date:  2006-08-04       Impact factor: 1.900

  1 in total