Literature DB >> 10709069

Embolic risk of the different stages of carotid bifurcation balloon angioplasty: an experimental study.

M Coggia1, O Goëau-Brissonnière, J L Duval, J P Leschi, M Letort, M D Nagel.   

Abstract

PURPOSE: Embolic events during carotid angioplasty are a challenging problem. This experimental study was undertaken to determine the embolic risk after each stage of carotid angioplasty procedure.
METHODS: Five ex vivo carotid artery balloon angioplasties were performed on fresh carotid specimens. The carotid specimens were obtained from five patients who underwent an internal carotid artery bypass for stenosis >75%. Before the endovascular maneuvers and after each stage of the procedures, the specimens were flushed with 20 mL of saline solution. Small particulate emboli (diameter, <60 microm) were searched in all the effluents according to the Coulter technique. After this procedure, each effluent was also submitted to scanning electron microscopy.
RESULTS: When the stenosis was crossed with the guidewire or the balloon catheter, the number and the mean diameter of embolic particles did not change with three plaques (CP1, CP2, and CP3) and were increased with two plaques (CP4 and CP5). The maximal size of particles was 220 microm (CP5). After balloon angioplasty, the number and the mean diameter of particles increased with CP1, CP2, and CP3. With CP4 and CP5, the number of particles decreased, but their size increased. The maximal size of particles was 1100 microm (CP4).
CONCLUSION: Carotid balloon angioplasty generates embolic particles after each stage of the procedure. Techniques of prevention should then be effective from the initial step of the angioplasty procedure, and the selection of patients for carotid angioplasty remains crucial.

Entities:  

Mesh:

Year:  2000        PMID: 10709069

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  12 in total

Review 1.  [Proximal protection systems using carotid artery stent].

Authors:  I Q Grunwald; U Dorenbeck; C Axmann; C Roth; T Struffert; W Reith
Journal:  Radiologe       Date:  2004-10       Impact factor: 0.635

2.  Effectiveness of mechanical endovascular thrombectomy in a model system of cerebrovascular occlusion.

Authors:  J Y Chueh; A K Wakhloo; M J Gounis
Journal:  AJNR Am J Neuroradiol       Date:  2012-05-03       Impact factor: 3.825

3.  Carotid intervention 3: the evidence for cerebral protection.

Authors:  Fabrizio Fanelli; Mario Bezzi; Emanuele Boatta; Roberto Passariello
Journal:  Semin Intervent Radiol       Date:  2007-06       Impact factor: 1.513

4.  Carotid angioplasty and stenting without protection devices: safety and efficacy concerns--single center experience.

Authors:  O Y Mansour; J Weber; W Niesen; M Schumacher; A Berlis
Journal:  Clin Neuroradiol       Date:  2011-05-12       Impact factor: 3.649

5.  Carotid artery stenting without angioplasty and cerebral protection: a single-center experience with up to 7 years' follow-up.

Authors:  S Baldi; T Zander; M Rabellino; G González; M Maynar
Journal:  AJNR Am J Neuroradiol       Date:  2011-02-24       Impact factor: 3.825

6.  Silent ischemia after neuroprotected percutaneous carotid stenting: a diffusion-weighted MRI study.

Authors:  P Piñero; A González; A Mayol; E Martínez; J R González-Marcos; F Boza; A Cayuela; A Gil-Peralta
Journal:  AJNR Am J Neuroradiol       Date:  2006 Jun-Jul       Impact factor: 3.825

7.  Detection of clinically silent infarcts after carotid endarterectomy by use of diffusion-weighted imaging.

Authors:  R J Feiwell; L Besmertis; R Sarkar; D A Saloner; J H Rapp
Journal:  AJNR Am J Neuroradiol       Date:  2001-04       Impact factor: 3.825

8.  Carotid stenting without use of balloon angioplasty and distal protection devices: preliminary experience in 100 cases.

Authors:  M Maynar; S Baldi; R Rostagno; T Zander; M Rabellino; R Llorens; J Alvarez; F Barajas
Journal:  AJNR Am J Neuroradiol       Date:  2007-08       Impact factor: 3.825

9.  Comparison of dual protection and distal filter protection as a distal embolic protection method during carotid artery stenting: a single-center carotid artery stenting experience.

Authors:  Yosuke Kajihara; Shigeyuki Sakamoto; Yoshihiro Kiura; Kazutoshi Mukada; Takahiro Chaki; Shiro Kajihara; Kaoru Kurisu
Journal:  Neurosurg Rev       Date:  2015-05-09       Impact factor: 3.042

10.  Comparison of anti-embolic protection with proximal balloon occlusion and filter devices during carotid artery stenting: clinical and procedural outcomes.

Authors:  Ersan Tatli; Ali Buturak; Yasemin Grunduz; Emir Dogan; Mustafa Alkan; Murat Sayin; Mustafa Yilmaztepe; Selcuk Atakay
Journal:  Postepy Kardiol Interwencyjnej       Date:  2013-09-16       Impact factor: 1.426

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.