Literature DB >> 10708772

A three-dimensional mechanical analysis of a stentless fibre-reinforced aortic valve prosthesis.

G Cacciola1, G W Peters, P J Schreurs.   

Abstract

Failure of bioprosthetic and synthetic three-leaflet valves has been shown to occur as a consequence of high tensile and bending stresses, acting on the leaflets during opening and closing. Moreover, in the stented prostheses, whether synthetic or biological, the absence of contraction of the aortic base, due to the rigid stent, causes the leaflets to be subjected to an unphysiological degree of flexure, which is related to calcification. It is shown that the absence of the stent, which gives a flexible aortic base and leaflet attachment, and leaflet fibre-reinforcement result in reduced stresses in the weaker parts of the leaflets in their closed configuration. It is postulated that this leads to a decrease of tears and perforations, which may result in a improved long-term behaviour. The effect of a flexible leaflet attachment and aortic base of a synthetic valve is investigated with a finite element model. Different fibre-reinforced structures are analysed with respect to the stresses that are likely to contribute to the failure of fibre-reinforced prostheses and compared with the results obtained for a stented prosthesis. Results show that for the stentless models a reduction of stresses up to 75% is obtained with respect to stented models with the same type of reinforcement.

Entities:  

Mesh:

Year:  2000        PMID: 10708772     DOI: 10.1016/s0021-9290(99)00222-5

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  12 in total

1.  Protocol for relative hydrodynamic assessment of tri-leaflet polymer valves.

Authors:  Sharan Ramaswamy; Manuel Salinas; Rob Carrol; Karla Landaburo; Xavier Ryans; Cynthia Crespo; Ailyn Rivero; Faris Al-Mousily; Curt DeGroff; Mark Bleiweis; Hitomi Yamaguchi
Journal:  J Vis Exp       Date:  2013-10-17       Impact factor: 1.355

Review 2.  In vivo imaging and computational analysis of the aortic root. Application in clinical research and design of transcatheter aortic valve systems.

Authors:  Paul Schoenhagen; Alexander Hill; Tim Kelley; Zoran Popovic; Sandra S Halliburton
Journal:  J Cardiovasc Transl Res       Date:  2011-04-12       Impact factor: 4.132

3.  Straightening of curved pattern of collagen fibers under load controls aortic valve shape.

Authors:  Peter E Hammer; Christina A Pacak; Robert D Howe; Pedro J del Nido
Journal:  J Biomech       Date:  2013-11-28       Impact factor: 2.712

4.  Design and validation of a novel bioreactor to subject aortic valve leaflets to side-specific shear stress.

Authors:  Ling Sun; Nalini M Rajamannan; Philippe Sucosky
Journal:  Ann Biomed Eng       Date:  2011-04-01       Impact factor: 3.934

Review 5.  Computational modeling of cardiac valve function and intervention.

Authors:  Wei Sun; Caitlin Martin; Thuy Pham
Journal:  Annu Rev Biomed Eng       Date:  2014-04-16       Impact factor: 9.590

Review 6.  Biomechanical Behavior of Bioprosthetic Heart Valve Heterograft Tissues: Characterization, Simulation, and Performance.

Authors:  Joao S Soares; Kristen R Feaver; Will Zhang; David Kamensky; Ankush Aggarwal; Michael S Sacks
Journal:  Cardiovasc Eng Technol       Date:  2016-08-09       Impact factor: 2.495

7.  Imaging analysis of collagen fiber networks in cusps of porcine aortic valves: effect of their local distribution and alignment on valve functionality.

Authors:  Mor Mega; Gil Marom; Rotem Halevi; Ashraf Hamdan; Danny Bluestein; Rami Haj-Ali
Journal:  Comput Methods Biomech Biomed Engin       Date:  2015-09-25       Impact factor: 1.763

8.  In vivo dynamic deformation of the mitral valve annulus.

Authors:  Chad E Eckert; Brett Zubiate; Mathieu Vergnat; Joseph H Gorman; Robert C Gorman; Michael S Sacks
Journal:  Ann Biomed Eng       Date:  2009-07-08       Impact factor: 3.934

9.  Reduced leaflet stress in the stentless quadrileaflet mitral valve: a finite element model.

Authors:  Jian-Gang Wang; Xing-Cheng Kuai; Bi-Qiao Ren; Guang-Fu Gong; Xin-Min Zhou
Journal:  PLoS One       Date:  2013-07-02       Impact factor: 3.240

10.  A bio-inspired microstructure induced by slow injection moulding of cylindrical block copolymers.

Authors:  Joanna Stasiak; Jacob Brubert; Marta Serrani; Sukumaran Nair; Francesco de Gaetano; Maria Laura Costantino; Geoff D Moggridge
Journal:  Soft Matter       Date:  2014-08-28       Impact factor: 3.679

View more