Biometry of the fetal heart between 10 and 17 weeks of gestation.

U Gembruch1, C Shi, J M Smrcek.   

Abstract

OBJECTIVES: Assessment of the dimensions of the cardiac chambers and the great arteries in the human fetus may be helpful in the prenatal diagnosis of congenital heart disease. The purpose of this prospective cross-sectional study was to compile normative data in fetal cardiac measurements in early pregnancy. The structure of the fetal heart was examined in 136 normal singleton fetuses between 10 and 17 weeks of gestation.
METHODS: The transversal heart diameter, both ventricular dimensions, interventricular septal thickness, heart area, heart circumference, thoracic diameter, thoracic circumference and thoracic area were measured in the four-chamber view during diastole. Diameters of the pulmonary trunk and ascending aorta were obtained in the short axis and long axis view during systole. Ultrasound examinations were performed with a 5.0-MHz transvaginal and/or transabdominal phased-array sector scanner.
RESULTS: The four-chamber view and the cross-over of the pulmonary artery and the aorta were adequately visualized in 44% of the fetuses at 10 weeks of gestation, in 75% at 11 weeks of gestation, in 93% at 12 weeks of gestation and in 100% of the fetuses at 13-17 weeks of gestation. Before 14 weeks of gestation transvaginal sonography was superior to the transabdominal sonography in visualization of the fetal heart and great arteries. After 14 weeks of gestation transabdominal sonography accurately demonstrated the structure of the fetal heart. The ratio of right and left ventricle (RV/LV) and the ratio of the pulmonary trunk and aorta (PT/AO) were constant during this period of gestation (approximately 1.00 and 1. 10, respectively). The ratio of the cardiac and thoracic area showed only a slight increase with advancing gestational age, but with significant correlation. The fetal heart rate showed a slow decrease from 167 to 150 bpm in this period of gestation. The transversal heart diameter, both ventricular dimensions, interventricular septal thickness, heart area, cardiothoracic diameter ratio, aortic diameter and the pulmonary trunk diameter showed a highly significant linear correlation to the gestational age and the biparietal diameter.
CONCLUSION: The advancing quality of ultrasound images allows fetal echocardiography in the first and early second trimester. Our normative data could be the basis of studying the development of cardiac structures in congenital heart disease and it might be helpful in the detection of some congenital heart defects in early pregnancy. Copyright 2000 S. Karger AG, Basel.

Entities:  

Mesh:

Year:  2000        PMID: 10705210     DOI: 10.1159/000020970

Source DB:  PubMed          Journal:  Fetal Diagn Ther        ISSN: 1015-3837            Impact factor:   2.587


  11 in total

1.  Development of the abdominal aorta and iliac arteries during the fetal period: a morphometric study.

Authors:  Gülnur Ozgüner; Osman Sulak
Journal:  Surg Radiol Anat       Date:  2010-07-11       Impact factor: 1.246

2.  STUDIES IN FETAL BEHAVIOR: REVISITED, RENEWED, AND REIMAGINED.

Authors:  Janet A DiPietro; Kathleen A Costigan; Kristin M Voegtline
Journal:  Monogr Soc Res Child Dev       Date:  2015-09

Review 3.  Cardiotocography and beyond: a review of one-dimensional Doppler ultrasound application in fetal monitoring.

Authors:  Faezeh Marzbanrad; Lisa Stroux; Gari D Clifford
Journal:  Physiol Meas       Date:  2018-08-14       Impact factor: 2.833

Review 4.  What is new in pediatric cardiology.

Authors:  Monesha L Gupta; M Regina Lantin-Hermoso; P Syamasundar Rao
Journal:  Indian J Pediatr       Date:  2003-01       Impact factor: 1.967

Review 5.  Advances in fetal cardiac imaging.

Authors:  M Sklansky
Journal:  Pediatr Cardiol       Date:  2004 May-Jun       Impact factor: 1.655

6.  Cardiovascular assessment of fetal mice by in utero echocardiography.

Authors:  Qing Yu; Linda Leatherbury; Xin Tian; C W Lo
Journal:  Ultrasound Med Biol       Date:  2008-03-06       Impact factor: 2.998

7.  The normal growth of the common iliac arteries in human fetuses - an anatomical, digital and statistical study.

Authors:  Michał Szpinda; Anna Szpinda; Alina Woźniak; Marcin Daroszewski; Celestyna Mila-Kierzenkowska
Journal:  Med Sci Monit       Date:  2012-03

8.  Screening for hemoglobin Bart's disease among fetuses at risk at mid-pregnancy using the fetal cardiac diameter to biparietal diameter ratio.

Authors:  Nopamas Thathan; Kuntharee Traisrisilp; Suchaya Luewan; Kasemsri Srisupundit; Fuanglada Tongprasert; Theera Tongsong
Journal:  BMC Pregnancy Childbirth       Date:  2014-07-16       Impact factor: 3.007

9.  Disproportionate cardiac hypertrophy during early postnatal development in infants born preterm.

Authors:  Christina Y L Aye; Adam J Lewandowski; Pablo Lamata; Ross Upton; Esther Davis; Eric O Ohuma; Yvonne Kenworthy; Henry Boardman; Samuel Wopperer; Alice Packham; Satish Adwani; Kenny McCormick; Aris T Papageorghiou; Paul Leeson
Journal:  Pediatr Res       Date:  2017-05-24       Impact factor: 3.756

Review 10.  Diagnostic Value of Fetal Echocardiography for Congenital Heart Disease: A Systematic Review and Meta-Analysis.

Authors:  Ya-Fei Zhang; Xian-Ling Zeng; En-Fa Zhao; Hong-Wei Lu
Journal:  Medicine (Baltimore)       Date:  2015-10       Impact factor: 1.817

View more