| Literature DB >> 10704039 |
M A Campanero1, B Calahorra, E García-Quétglas, A López-Ocáriz, J Honorato.
Abstract
A simple method for the rapid estimation of acetaminophen in plasma is described here. p-Propionamidophenol was used as internal standard. The assay involved a single ethyl acetate extraction and liquid chromatographic analysis at a wavelength of 242 nm using a reversed-phase encapped column, with a mobile phase of acetonitrile and 0.005 M potassium dihydrogen phosphate adjusted at pH 3.00. The limit of quantitation of acetaminophen by this method was 0.05 microg ml(-1), only 0.1 ml of the plasma sample was required for the determination. The calibration graph was linear from 0.05 to 100 microg ml(-1). Intra and inter-day precision (CV) did not exceed 8.93%. Mean recoveries of 90.31% with a CV of 1.38% were obtained. Applicability of the method was demonstrated by a pharmacokinetic study in normal volunteers who received 2 mg propacetamol.Entities:
Mesh:
Substances:
Year: 1999 PMID: 10704039 DOI: 10.1016/s0731-7085(99)00051-5
Source DB: PubMed Journal: J Pharm Biomed Anal ISSN: 0731-7085 Impact factor: 3.935