Literature DB >> 10704037

Simultaneous spectrophotometric determination of rutin, quercetin and ascorbic acid in drugs using a Kalman Filter approach.

H N Hassan1, B N Barsoum, I H Habib.   

Abstract

A UV-spectrophotometric analysis of severely overlapped spectra yielded by anti-capillary fragility pharmaceutical materials, viz. rutin, quercetin and ascorbic acid, in authentic mixtures and in tablets or soft elastic capsules was proposed. The method was based on Kalman Filter calibration of either orthogonal experimental design, i.e. standard solutions containing only one component at a time, or non-orthogonal experimental design, i.e. standard solutions containing more than one component. This calibration was followed by quantitative determinations of two- and three-component mixtures in synthetic mixtures or in oral dosages within the concentration range 2-10 microg ml(-1). A statistical analysis of the results was reported.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10704037     DOI: 10.1016/s0731-7085(99)00048-5

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  6 in total

1.  One-step synthesis of a Methylene Blue@ZIF-8-reduced graphene oxide nanocomposite and its application to electrochemical sensing of rutin.

Authors:  Zonghua Wang; Gege Yu; Jianfei Xia; Feifei Zhang; Qingyun Liu
Journal:  Mikrochim Acta       Date:  2018-05-03       Impact factor: 5.833

2.  Electrochemical behavior and determination of rutin on modified carbon paste electrodes.

Authors:  Pavla Macikova; Vladimir Halouzka; Jan Hrbac; Petr Bartak; Jana Skopalova
Journal:  ScientificWorldJournal       Date:  2012-04-30

3.  Sensitive fluorometric method for the determination of rutin in combined tablet dosage form.

Authors:  S F Liu
Journal:  Indian J Pharm Sci       Date:  2013-09       Impact factor: 0.975

4.  A fungus-derived biomass porous carbon-MnO2 nanocomposite-modified electrode for the voltammetric determination of rutin.

Authors:  Hui Cheng; Juan Liu; Yunxiu Sun; Ting Zhou; Qiuyue Yang; Shuyao Zhang; Xiaoping Zhang; Guangjiu Li; Wei Sun
Journal:  RSC Adv       Date:  2020-11-20       Impact factor: 4.036

5.  A molecularly imprinted polymer with incorporated graphene oxide for electrochemical determination of quercetin.

Authors:  Si Sun; Mengqi Zhang; Yijun Li; Xiwen He
Journal:  Sensors (Basel)       Date:  2013-04-25       Impact factor: 3.576

6.  Comparative Study of Novel Ratio Spectra and Isoabsorptive Point Based Spectrophotometric Methods: Application on a Binary Mixture of Ascorbic Acid and Rutin.

Authors:  Hany W Darwish; Ahmed H Bakheit; Ibrahim A Naguib
Journal:  J Anal Methods Chem       Date:  2016-01-18       Impact factor: 2.193

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.