Literature DB >> 10703961

Interference of magnetic resonance imaging contrast agents with the serum calcium measurement technique using colorimetric reagents.

J Lin1, J M Idee, M Port, A Diai, C Berthommier, M Robert, I Raynal, L Devoldere, C Corot.   

Abstract

A possible interaction between either linear (Gd-DTPA-BMA and Gd-DTPA) or macrocyclic (Gd-DOTA) gadolinium complexes used as magnetic resonance imaging (MRI) contrast agents and colorimetric technique reagents for the measurement of serum calcium was evaluated on human serum pools, and its mechanism was investigated by means of UV spectrometry and electro-spray ionization mass spectrometry (ESI-MS). The highest concentration tested was 2.5 mM (corresponding to a putative strictly intravascular distribution of the compound) and the lowest dose was 0.2 mM (i.e. about two elimination half lives). Serum calcium was dosed in duplicate by conventional colorimetric techniques involving o-cresol-phthalein complexone (OCP) or methylthymol blue (MTB) as reagents. No interference was detected when mixing Gd DOTA with serum, whatever the concentration. Gd DTPA (2.5 mM) did not interfere with the colorimetric technique either. Conversely, the Gd DTPA-BMA solution induced a concentration-related variation in apparent calcium levels. In the UV experiments, solutions of 2.5 mM MRI contrast media were mixed with OCP or MTB and UV absorption spectra were recorded between 400 and 800 nm. For Gd-DOTA/OCP and Gd-DOTA/MTB, no significant variations in the absorbance were detected. However, in the presence of Gd DTPA BMA, the absorbance of OCP and MTB showed substantial and immediate variations over time. The ESI-MS studies showed a complete displacement of Gd3+ ion in the case of Gd-DTPA BMA. In the presence of OCP, we observed the disappearance of Gd-DTPA BMA and the formation of the free ligand DTPA BMA and a new complex Gd OCP with an original stoichiometry of 2/2. Such a phenomenon did not occur in the case of Gd DOTA and Gd DTPA. The decomplexation of Gd-DTPA BMA in the presence of OCP can probably be explained by the weaker thermodynamic stability of Gd-DTPA BMA compared to that of Gd-DOTA and Gd DTPA.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10703961     DOI: 10.1016/s0731-7085(99)00188-0

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  6 in total

1.  Spurious hypocalcemia after gadodiamide-enhanced magnetic resonance imaging: a case report and review of the literature.

Authors:  Christopher D Moore; Robert C Newman; James G Caridi
Journal:  Rev Urol       Date:  2006

2.  New method for calcium on the ADVIA analyzer is free from interference of gadolinium-type contrast agents.

Authors:  Pradip Datta; Amitava Dasgupta
Journal:  J Clin Lab Anal       Date:  2009       Impact factor: 2.352

Review 3.  Biochemical safety profiles of gadolinium-based extracellular contrast agents and nephrogenic systemic fibrosis.

Authors:  Hale Ersoy; Frank J Rybicki
Journal:  J Magn Reson Imaging       Date:  2007-11       Impact factor: 4.813

4.  Analytical Interference by Contrast Agents in Biochemical Assays.

Authors:  Sigrid Otnes; Niels Fogh-Andersen; Janne Rømsing; Henrik S Thomsen
Journal:  Contrast Media Mol Imaging       Date:  2017-04-10       Impact factor: 3.161

Review 5.  Interference of medical contrast media on laboratory testing.

Authors:  Giuseppe Lippi; Massimo Daves; Camilla Mattiuzzi
Journal:  Biochem Med (Zagreb)       Date:  2014-02-15       Impact factor: 2.313

6.  Analytical interference in serum iron determination reveals iron versus gadolinium transmetallation with linear gadolinium-based contrast agents.

Authors:  Nathalie Fretellier; Nathalie Poteau; Cécile Factor; Jean-François Mayer; Christelle Medina; Marc Port; Jean-Marc Idée; Claire Corot
Journal:  Invest Radiol       Date:  2014-12       Impact factor: 6.016

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.