False diagnosis and needless therapy of presumed malignant disease in women with false-positive human chorionic gonadotropin concentrations.

S Rotmensch1, L A Cole.   

Abstract

BACKGROUND: 12 women were diagnosed of having postgestational choriocarcinoma on the basis of persistently positive human chorionic gonadotropin (hCG) test results in the absence of pregnancy. Most of the women had extirpative surgery or chemotherapy, or both, without significant diminution in hCG titre. Our aim was to assess whether the hCG concentrations were false-positive test results.
METHODS: Samples were tested for hCG, hCG free beta subunit, and hCG beta-core fragment. Assay kinetics were also assessed, and samples were tested independently by competitive RIA. False-positive hCG concentrations were identified by two criteria: detection of hCG in serum and lack of detection of hCG and its degradation products in urine; and wide variations in results for different hCG assays. We corroborated false-positive hCG values by the lack of parallel changes in hCG results when serum was diluted, by false detection of other antigens, and by failure to detect hCG with in-house assays.
FINDINGS: All 12 women met both criteria for false-positive hCG, and all had corroborating findings. In all 12 cases, a false diagnosis had been made, and most of the women had been subjected to needless surgery or chemotherapy. Assay kinetics indicated that heterophilic antibodies were responsible for the false-positive results. As a result of our findings all further therapy was stopped.
INTERPRETATION: Current protocols for the diagnosis and treatment of choriocarcinoma should be modified to include a compulsory test for hCG in urine.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10703803     DOI: 10.1016/S0140-6736(00)01324-6

Source DB:  PubMed          Journal:  Lancet        ISSN: 0140-6736            Impact factor:   79.321


  28 in total

1.  Wrong biochemistry results.

Authors:  A A Ismail; J H Barth
Journal:  BMJ       Date:  2001-09-29

2.  Heterophile antibody interference in a multiplexed fluorescent microsphere immunoassay for quantitation of cytokines in human serum.

Authors:  Thomas B Martins; Brian M Pasi; Christine M Litwin; Harry R Hill
Journal:  Clin Diagn Lab Immunol       Date:  2004-03

3.  Interlaboratory evaluation of automated, multiplexed peptide immunoaffinity enrichment coupled to multiple reaction monitoring mass spectrometry for quantifying proteins in plasma.

Authors:  Eric Kuhn; Jeffrey R Whiteaker; D R Mani; Angela M Jackson; Lei Zhao; Matthew E Pope; Derek Smith; Keith D Rivera; N Leigh Anderson; Steven J Skates; Terry W Pearson; Amanda G Paulovich; Steven A Carr
Journal:  Mol Cell Proteomics       Date:  2011-12-22       Impact factor: 5.911

Review 4.  Replacing immunoassays with tryptic digestion-peptide immunoaffinity enrichment and LC-MS/MS.

Authors:  Jessica O Becker; Andrew N Hoofnagle
Journal:  Bioanalysis       Date:  2012-02       Impact factor: 2.681

5.  What makes D-dimer assays suspicious-heterophilic antibodies?

Authors:  Ying Wu; Ying-Xiu Xiao; Teng-Yi Huang; Xian-Yan Zhang; Huan-Bing Zhou; Xue-Xuan Zhang; Ying-E Wu
Journal:  J Clin Lab Anal       Date:  2018-10-15       Impact factor: 2.352

6.  Frequent false positive beta human chorionic gonadotropin tests in immunoglobulin A deficiency.

Authors:  A K Knight; T Bingemann; L Cole; C Cunningham-Rundles
Journal:  Clin Exp Immunol       Date:  2005-08       Impact factor: 4.330

7.  When laboratory tests can mislead even when they appear plausible.

Authors:  Adel Aa Ismail
Journal:  Clin Med (Lond)       Date:  2017-07       Impact factor: 2.659

Review 8.  New discoveries on the biology and detection of human chorionic gonadotropin.

Authors:  Laurence A Cole
Journal:  Reprod Biol Endocrinol       Date:  2009-01-26       Impact factor: 5.211

9.  Interferences in immunoassay.

Authors:  Jill Tate; Greg Ward
Journal:  Clin Biochem Rev       Date:  2004-05

Review 10.  Clinical review: improving the measurement of serum thyroglobulin with mass spectrometry.

Authors:  Andrew N Hoofnagle; Mara Y Roth
Journal:  J Clin Endocrinol Metab       Date:  2013-02-28       Impact factor: 5.958