Literature DB >> 10701512

Photon beam characterization and modelling for Monte Carlo treatment planning.

J Deng1, S B Jiang, A Kapur, J Li, T Pawlicki, C M Ma.   

Abstract

Photon beams of 4, 6 and 15 MV from Varian Clinac 2100C and 2300C/D accelerators were simulated using the EGS4/BEAM code system. The accelerators were modelled as a combination of component modules (CMs) consisting of a target, primary collimator, exit window, flattening filter, monitor chamber, secondary collimator, ring collimator, photon jaws and protection window. A full phase space file was scored directly above the upper photon jaws and analysed using beam data processing software, BEAMDP, to derive the beam characteristics, such as planar fluence, angular distribution, energy spectrum and the fractional contributions of each individual CM. A multiple-source model has been further developed to reconstruct the original phase space. Separate sources were created with accurate source intensity, energy, fluence and angular distributions for the target, primary collimator and flattening filter. Good agreement (within 2%) between the Monte Carlo calculations with the source model and those with the original phase space was achieved in the dose distributions for field sizes of 4 cm x 4 cm to 40 cm x 40 cm at source surface distances (SSDs) of 80-120 cm. The dose distributions in lung and bone heterogeneous phantoms have also been found to be in good agreement (within 2%) for 4, 6 and 15 MV photon beams for various field sizes between the Monte Carlo calculations with the source model and those with the original phase space.

Mesh:

Year:  2000        PMID: 10701512     DOI: 10.1088/0031-9155/45/2/311

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  15 in total

1.  A measurement-based generalized source model for Monte Carlo dose simulations of CT scans.

Authors:  Xin Ming; Yuanming Feng; Ransheng Liu; Chengwen Yang; Li Zhou; Hezheng Zhai; Jun Deng
Journal:  Phys Med Biol       Date:  2017-01-12       Impact factor: 3.609

2.  Modification and validation of an analytical source model for external beam radiotherapy Monte Carlo dose calculations.

Authors:  Scott E Davidson; Jing Cui; Stephen Kry; Joseph O Deasy; Geoffrey S Ibbott; Milos Vicic; R Allen White; David S Followill
Journal:  Med Phys       Date:  2016-08       Impact factor: 4.071

Review 3.  Monte Carlo methods for device simulations in radiation therapy.

Authors:  Hyojun Park; Harald Paganetti; Jan Schuemann; Xun Jia; Chul Hee Min
Journal:  Phys Med Biol       Date:  2021-09-14       Impact factor: 4.174

4.  Adapted Prescription Dose for Monte Carlo Algorithm in Lung SBRT: Clinical Outcome on 205 Patients.

Authors:  Jean-Emmanuel Bibault; Xavier Mirabel; Thomas Lacornerie; Emmanuelle Tresch; Nick Reynaert; Eric Lartigau
Journal:  PLoS One       Date:  2015-07-24       Impact factor: 3.240

5.  Development and reproducibility evaluation of a Monte Carlo-based standard LINAC model for quality assurance of multi-institutional clinical trials.

Authors:  Muhammad Nauman Usmani; Hideki Takegawa; Masaaki Takashina; Hodaka Numasaki; Masaki Suga; Yusuke Anetai; Keita Kurosu; Masahiko Koizumi; Teruki Teshima
Journal:  J Radiat Res       Date:  2014-06-23       Impact factor: 2.724

6.  A single-source photon source model of a linear accelerator for Monte Carlo dose calculation.

Authors:  Obioma Nwankwo; Gerhard Glatting; Frederik Wenz; Jens Fleckenstein
Journal:  PLoS One       Date:  2017-09-08       Impact factor: 3.240

7.  Monte Carlo Investigation of Photon Beam Characteristics and its Variation with Incident Electron Beam Parameters for Indigenous Medical Linear Accelerator.

Authors:  Subhalaxmi Mishra; P K Dixit; T Palani Selvam; Sanket S Yavalkar; D D Deshpande
Journal:  J Med Phys       Date:  2018 Jan-Mar

8.  Measurement comparison and Monte Carlo analysis for volumetric-modulated arc therapy (VMAT) delivery verification using the ArcCHECK dosimetry system.

Authors:  Mu-Han Lin; Sion Koren; Iavor Veltchev; Jinsheng Li; Lu Wang; Robert A Price; C-M Ma
Journal:  J Appl Clin Med Phys       Date:  2013-05-06       Impact factor: 2.102

9.  Intermediate Megavoltage Photon Beams for Improved Lung Cancer Treatments.

Authors:  Ying Zhang; Yuanming Feng; Munir Ahmad; Xin Ming; Li Zhou; Jun Deng
Journal:  PLoS One       Date:  2015-12-16       Impact factor: 3.752

10.  Energy Modulated Photon Radiotherapy: A Monte Carlo Feasibility Study.

Authors:  Ying Zhang; Yuanming Feng; Xin Ming; Jun Deng
Journal:  Biomed Res Int       Date:  2016-02-09       Impact factor: 3.246

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.