Literature DB >> 10701261

An LC-MS-MS method for the comprehensive analysis of cocaine and cocaine metabolites in meconium.

Y Xia1, P Wang, M G Bartlett, H M Solomon, K L Busch.   

Abstract

A sensitive, precise, and accurate liquid chromatography-mass spectrometry (LC-MS-MS) method was developed to quantitate cocaine and cocaine metabolites, which were simultaneously extracted from suspected drug-positive meconium samples using solid-phase extraction. The ability to analyze cocaine and multiple cocaine metabolites in meconium makes this method a powerful tool for the study of cocaine exposure and metabolism in neonates. Of 22 samples, only 1 did not show the presence of cocaine or any metabolite of cocaine. The identified metabolites varied both qualitatively and quantitatively between samples. Ecgonine appears to hold the most promise as a diagnostic marker compound for neonatal cocaine exposure as this metabolite was present in 21 of 21 of the positive samples tested, and at a relatively high median concentration. However, a core group of eight metabolites (present in at least 20 of 21 positive samples) was identified that appears to possess the greatest utility for determining cocaine exposure. Finally, the use of this method for assessment of the magnitude of fetal cocaine exposure was demonstrated.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10701261     DOI: 10.1021/ac990201p

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  6 in total

1.  Development and validation of a liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry method for simultaneous analysis of 10 amphetamine-, methamphetamine- and 3,4-methylenedioxymethamphetamine-related (MDMA) analytes in human meconium.

Authors:  Tamsin Kelly; Teresa R Gray; Marilyn A Huestis
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2008-04-04       Impact factor: 3.205

2.  Fast quantitative detection of cocaine in beverages using nanoextractive electrospray ionization tandem mass spectrometry.

Authors:  Bin Hu; Xuejiao Peng; Shuiping Yang; Haiwei Gu; Huanwen Chen; Yanfu Huan; Tingting Zhang; Xiaolin Qiao
Journal:  J Am Soc Mass Spectrom       Date:  2009-10-29       Impact factor: 3.109

Review 3.  Bioanalytical procedures for monitoring in utero drug exposure.

Authors:  Teresa Gray; Marilyn Huestis
Journal:  Anal Bioanal Chem       Date:  2007-03-17       Impact factor: 4.142

4.  Development and validation of the first liquid chromatography-tandem mass spectrometry assay for simultaneous quantification of multiple antiretrovirals in meconium.

Authors:  Sarah K Himes; Karl B Scheidweiler; Katherine Tassiopoulos; Deborah Kacanek; Rohan Hazra; Kenneth Rich; Marilyn A Huestis
Journal:  Anal Chem       Date:  2013-01-14       Impact factor: 6.986

5.  A liquid chromatography tandem mass spectrometry method for the simultaneous quantification of 20 drugs of abuse and metabolites in human meconium.

Authors:  Teresa R Gray; Diaa M Shakleya; Marilyn A Huestis
Journal:  Anal Bioanal Chem       Date:  2009-02-26       Impact factor: 4.142

6.  Real-time cellular exometabolome analysis with a microfluidic-mass spectrometry platform.

Authors:  Christina C Marasco; Jeffrey R Enders; Kevin T Seale; John A McLean; John P Wikswo
Journal:  PLoS One       Date:  2015-02-27       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.