Literature DB >> 10699732

Imaging of head and neck tumors--methods: CT, spiral-CT, multislice-spiral-CT.

U Baum1, H Greess, M Lell, A Nömayr, M Lenz.   

Abstract

Spiral-CT is standard for imaging neck tumors. In correspondence with other groups we routinely use spiral-CT with thin slices (3 mm), a pitch of 1.3-1.5 and an overlapping reconstruction increment (2-3 mm). In patients with dental fillings a short additional spiral parallel to the corpus of the mandible reduces artifacts behind the dental arches and improves the diagnostic value of CT. For the assessment of the base of the skull, the orbital floor, the palate and paranasal sinuses an additional examination in the coronal plane is helpful. Secondary coronal reconstructions of axial scans are helpful in the evaluation of the crossing of the midline by small tumors of the tongue base or palate. For an optimal vascular or tissue contrast a sufficient volume of contrast medium and a start delay greater than 70-80 s are necessary. In our opinion the best results can be achieved with a volume of 150 ml, a flow of 2.5 ml/s and a start delay of 80 s. Dynamic enhanced CT is only necessary in some special cases. There is clear indication for dynamic enhanced CT where a glomus tumor is suspected. Additional functional CT imaging during i-phonation and/or Valsalva's maneuver are of great importance to prove vocal cords mobility. Therefore, imaging during i-phonation is an elemental part of every thorough examination of the hypopharynx and larynx region. Multislice-spiral-CT allows almost isotropic imaging of the head and neck region and improves the assessment of tumor spread and lymph node metastases in arbitrary oblique planes. Thin structures (the base of the skull, the orbital floor, the hard palate) as well as the floor of the mouth can be evaluated sufficiently with multiplanar reformations. Usually, additional coronal scanning is not necessary with multislice-spiral-CT. Multislice-spiral-CT is especially advantageous in defining the critical relationships of tumor and lymph node metastases and for functional imaging of the hypopharynx and larynx not only in the transverse plane but also in the coronal plane.

Entities:  

Mesh:

Year:  2000        PMID: 10699732     DOI: 10.1016/s0720-048x(99)00139-4

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  8 in total

Review 1.  Evaluation of the patient with hoarseness.

Authors:  A Van der Goten
Journal:  Eur Radiol       Date:  2004-04-14       Impact factor: 5.315

Review 2.  Multi-detector CT: head and neck imaging.

Authors:  Martin G Mack; Jörn O Balzer; Christopher Herzog; Thomas J Vogl
Journal:  Eur Radiol       Date:  2003-12       Impact factor: 5.315

3.  Unknown internal carotid artery atherosclerotic stenoses detected with biphasic multidetector computed tomography for head and neck cancer.

Authors:  Nicola Flor; Francesco Sardanelli; Simone Soldi; Giuseppe Franceschelli; Caterina Missiroli; Fiora De Paoli; Gianpaolo Cornalba
Journal:  Eur Radiol       Date:  2005-12-01       Impact factor: 5.315

4.  Comparison between computed tomography and clinical evaluation in tumour/node stage and follow-up of oral cavity and oropharyngeal cancer.

Authors:  P T Figueiredo; A F Leite; A C Freitas; L A Nascimento; M G Cavalcanti; N S Melo; E N Guerra
Journal:  Dentomaxillofac Radiol       Date:  2010-03       Impact factor: 2.419

5.  Cone beam computed tomography and ultrasonography imaging of benign intraosseous jaw lesion: a prospective radiopathological study.

Authors:  Ibrahim Sevki Bayrakdar; Ahmet Berhan Yilmaz; Fatma Caglayan; Umit Ertas; Cemal Gundogdu; Ismail Gumussoy
Journal:  Clin Oral Investig       Date:  2017-10-18       Impact factor: 3.573

6.  Role of diagnostic imaging to malignant sinus tumors in presurgical staging.

Authors:  E Fanucci; V Fiaschetti; N Fusco; S Viarani; M Gargari; A Barlattani; E P Assako; G Simonetti
Journal:  Oral Implantol (Rome)       Date:  2009-02-01

7.  Comparison of different patient positioning strategies to minimize shoulder girdle artifacts in head and neck CT.

Authors:  Stefan Wirth; Thomas Meindl; Marcus Treitl; Klaus-Jürgen Pfeifer; Maximilian Reiser
Journal:  Eur Radiol       Date:  2006-03-17       Impact factor: 5.315

8.  Intra-arterial versus intra venous contrast-enhanced computed tomography of the equine head.

Authors:  Casper P Crijns; Yseult Baeumlin; Lieve De Rycke; Bart J G Broeckx; Lieven Vlaminck; Erik H J Bergman; Henri van Bree; Ingrid Gielen
Journal:  BMC Vet Res       Date:  2016-01-07       Impact factor: 2.741

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.