Literature DB >> 10698553

Analysis of benzalkonium chloride and its homologs: HPLC versus HPCE.

S J Prince1, H J McLaury, L V Allen, P McLaury.   

Abstract

Benzalkonium chloride (BAK) is a mixture of alkylbenzyldimethylammonium chloride homologs with n-C,2H25, n-C,4H29, and n-C16H33 comprising a major portion of the alkyl groups present. An analytical method for BAK must differentiate and quantitate the homologs in the BAK mixture. Reversed-phase high performance liquid chromatography (HPLC) separates compounds based on their affinity for a nonpolar column, which is a direct correlation to the compounds' polarity. High performance capillary electrophoresis (HPCE), however, separates compounds in an electric field according to their charge and size. The BAK homologs are suitable for separation by either of these methods because their polarity and sizes differ significantly. The HPLC method employed a mobile phase of 60% acetonitrile and 40% 0.1 M sodium acetate buffer pH 5 pumped at 1.0 ml min(-1), a 4.6 x 250 mm cyano column with 5 microm packing, and UV detection at 254 nm. The HPCE method utilized a run buffer of 30% acetonitrile and 70% 0.05 M sodium phosphate pH 3.06, a 50 microm x 20 cm open silica capillary, 7.5 kV electric field and UV detection at 214 nm. Both HPLC and HPCE demonstrated good linearity in the range of 0.025 to 0.8 mg ml(-1) with r2 values of approximately 0.99. The HPLC method produced good separation of the homolog peaks with a total analysis time of 25 min. HPCE run time was less than 5 min and demonstrated good separation of the three homologs. The HPLC method, however, was superior to HPCE in the areas of sensitivity and precision. The HPLC has been extensively used in the routine quantitation and qualitation of benzalkonium chloride concentrations in various products; however, long analysis times make this method inefficient. The HPCE method produced comparable results to the HPLC method but with much shorter analysis times. An HPCE analysis method, as presented here, may prove to be a much more useful and efficient method for the analysis of benzalkonium chloride and its homologs.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10698553     DOI: 10.1016/s0731-7085(98)00187-3

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  5 in total

1.  In vivo studies of the effectiveness of novel N-halomethylated and non-halomethylated quaternary ammonium salts in the topical treatment of cutaneous leishmaniasis.

Authors:  Maritza Fernandez; Javier Murillo; Luz Amalia Ríos-Vásquez; Rogelio Ocampo-Cardona; David L Cedeño; Marjorie A Jones; Iván D Velez; Sara M Robledo
Journal:  Parasitol Res       Date:  2017-12-11       Impact factor: 2.289

2.  Sampling and analysis of quaternary ammonium compounds (QACs) traces in indoor atmosphere.

Authors:  Guillaume Vincent; Marie Christine Kopferschmitt-Kubler; Philippe Mirabel; Gabrielle Pauli; Maurice Millet
Journal:  Environ Monit Assess       Date:  2006-12-16       Impact factor: 2.513

3.  Determination of benzalkonium chloride in viscous ophthalmic drops of azithromycin by high-performance liquid chromatography.

Authors:  Yan Shen; Sheng-jie Xu; Shi-chun Wang; Jia-sheng Tu
Journal:  J Zhejiang Univ Sci B       Date:  2009-12       Impact factor: 3.066

4.  Preparation of benzalkonium salts differing in the length of a side alkyl chain.

Authors:  Kamil Kuca; Jan Marek; Petr Stodulka; Kamil Musilek; Petra Hanusova; Martina Hrabinova; Daniel Jun
Journal:  Molecules       Date:  2007-10-24       Impact factor: 4.411

5.  Assessment of respiratory and systemic toxicity of Benzalkonium chloride following a 14-day inhalation study in rats.

Authors:  Hye-Yeon Choi; Yong-Hoon Lee; Cheol-Hong Lim; Yong-Soon Kim; In-Seop Lee; Ji-Min Jo; Ha-Young Lee; Hyo-Geun Cha; Hee Jong Woo; Dong-Seok Seo
Journal:  Part Fibre Toxicol       Date:  2020-01-28       Impact factor: 9.400

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.