Bypass flow, mean arterial pressure, and cerebral perfusion during cardiopulmonary bypass in dogs.

H Sungurtekin1, U S Boston, D J Cook.   

Abstract

OBJECTIVE: To determine if normal cardiopulmonary bypass (CPB) pump flows maintain cerebral perfusion in the context of reduced mean arterial pressure at 33 degrees C.
DESIGN: A prospective investigation.
SETTING: Animal CPB research laboratory. PARTICIPANTS: Seven dogs that underwent CPB.
INTERVENTIONS: Seven dogs underwent CPB at 33 degrees C using alpha-stat management and a halothane, fentanyl-midazolam anesthetic. Cerebral blood flow was measured using the sagittal sinus outflow technique. After control measurements at 70 mm Hg, cerebral physiologic values were determined under four conditions in random order: (1) mean arterial pressure of 60 mm Hg achieved by a reduction in pump flow, (2) mean arterial pressure of 60 mmHg determined by partial opening of a femoral arterial-to-venous reservoir shunt, (3) mean arterial pressure of 45 mm Hg by reduced pump flow, and (4) mean arterial pressure of 45 mm Hg by shunt. A 9F femoral arterial-to-venous reservoir shunt was controlled by a screw clamp.
MEASUREMENTS AND MAIN RESULTS: Except for the controlled variables of mean arterial pressure and bypass flow, physiologic determinants of cerebral blood flow (temperature, PaCO2 and hematocrit) did not differ under any of the CPB conditions. Pump flow per se was not a determinant of cerebral perfusion. Cerebral blood flow and cerebral oxygen delivery did not differ with changes in pump flow if mean arterial pressure did not differ. Cerebral blood flow depended on mean arterial pressure under all pump flow conditions, however.
CONCLUSIONS: Over the range of flows typical in adult CPB at 33 degrees C, pump flow does not have an effect on cerebral perfusion independent of its effect on mean arterial pressure. A targeted pump flow per se is not sufficient to maintain cerebral perfusion if mean arterial blood pressure is reduced.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10698388     DOI: 10.1016/s1053-0770(00)90051-x

Source DB:  PubMed          Journal:  J Cardiothorac Vasc Anesth        ISSN: 1053-0770            Impact factor:   2.628


  2 in total

1.  Evaluation of hemodynamic and regional tissue perfusion effects of minimized extracorporeal circulation (MECC).

Authors:  Adrian Bauer; Claudius Diez; Jens Schubel; Nagi El-Shouki; Dietrich Metz; T Eberle; Harald Hausmann
Journal:  J Extra Corpor Technol       Date:  2010-03

2.  Investigation of the Relationship between Cerebral Near-Infrared Spectroscopy Measurements and Cerebrovascular Event in Coronary Artery Bypass Grafting Operation in Patients without Carotid Stenosis and Patients with Carotid Stenosis below Surgical Margins.

Authors:  Ceyhun Coskun; Ferhat Borulu; Izzet Emir; Muhammed Hanedan; Ilker Mataraci
Journal:  Braz J Cardiovasc Surg       Date:  2020-08-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.