Literature DB >> 10696791

The effect of heterogeneity of lung structure on particle deposition in the rat lung.

W Hofmann1, B Asgharian, R Bergmann, S Anjilvel, F J Miller.   

Abstract

Differences in particle deposition patterns between human and rat lungs may be attributed primarily to their differences in breathing patterns and airway morphology. Heterogeneity of lung structure is expected to impact acinar particle deposition in the rat. Two different morphometric models of the rat lung were used to compute particle deposition in the acinar airways: the multiple-path lung (MPL) model (Anjilvel and Asgharian, 1995, Fundam. Appl. Toxicol. 28, 41-50) with a fixed airway geometry, and the stochastic lung (SL) model (Koblinger and Hofmann, 1988, Anat. Rec. 221, 533-539) with a randomly selected branching structure. In the MPL model, identical acini with a symmetric subtree (Yeh et aL, 1979, Anat. Rec. 195, 483-492) were attached to each terminal bronchiole, while the respiratory airways in the SL model are represented by an asymmetric stochastic subtree derived from morphometric data on the Sprague-Dawley rat (Koblinger et al., 1995, J. Aerosol. Med. 8, 7-19). In addition to the original MPL and SL models, a hybrid lung model was also used, based on the MPL bronchial tree and the SL acinar structure. Total and regional deposition was calculated for a wide range of particle sizes under quiet and heavy breathing conditions. While mean total bronchial and acinar deposition fractions were similar for the three models, the SL and hybrid models predicted a substantial variation in particle deposition among different acini. The variances of acinar deposition in the MPL model were consistently much smaller than those for the SL and the hybrid lung model. The similarity of acinar deposition variations in the two latter models and their independence on the breathing pattern suggests that the heterogeneity of the acinar airway structure is primarily responsible for the heterogeneity of acinar particle deposition.

Entities:  

Mesh:

Year:  2000        PMID: 10696791     DOI: 10.1093/toxsci/53.2.430

Source DB:  PubMed          Journal:  Toxicol Sci        ISSN: 1096-0929            Impact factor:   4.849


  5 in total

1.  Micron-sized intrapulmonary particle deposition in the developing rat lung.

Authors:  Holger Schulz; Gunter Eder; Ines Bolle; Akira Tsuda; Stefan Karrasch
Journal:  J Appl Physiol (1985)       Date:  2011-12-08

2.  Modeling the dynamics of airway constriction: effects of agonist transport and binding.

Authors:  Samir D Amin; Arnab Majumdar; Urs Frey; Béla Suki
Journal:  J Appl Physiol (1985)       Date:  2010-05-27

3.  Nociceptive pulmonary-cardiac reflexes are altered in the spontaneously hypertensive rat.

Authors:  J Shane Hooper; Katherine R Stanford; Pierina A Alencar; Natascha G Alves; Jerome W Breslin; Jay B Dean; Kendall F Morris; Thomas E Taylor-Clark
Journal:  J Physiol       Date:  2019-05-30       Impact factor: 5.182

4.  Ventilation Heterogeneity and Its Association with Nodule Formation Among Participants in the National Lung Screening Trial-A Preliminary Investigation.

Authors:  David A Kaminsky; Nirav Daphtary; Raul S J Estepar; Taka Ashikaga; Lukas Mikulic; Jeffrey Klein; C Matthew Kinsey
Journal:  Acad Radiol       Date:  2019-08-27       Impact factor: 5.482

5.  Systems Pharmacology Approach for Prediction of Pulmonary and Systemic Pharmacokinetics and Receptor Occupancy of Inhaled Drugs.

Authors:  E Boger; N Evans; M Chappell; A Lundqvist; P Ewing; A Wigenborg; M Fridén
Journal:  CPT Pharmacometrics Syst Pharmacol       Date:  2016-04-14
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.