Literature DB >> 10696711

Development and preliminary clinical tests of an impedance sensing VDD recording pacemaker for diagnosis and research.

D R Edgar1, J M Horwood, D J Woollons, J Baker, D B Shaw.   

Abstract

Episodes of serious but infrequently occurring cardiac arrhythmias can be difficult to detect and analyse, even with modern Holter monitoring. A previous diagnostic pacemaker developed by this group provided VVI pacing therapy and recorded intracardiac ECG signals but had no atrial sensing or impedance measuring capability. A new external diagnostic pacemaker system is described that has been developed to assist in diagnosing intermittent arrhythmias by selectively recording intracardiac signals. Unlike other ambulatory monitors, in addition to recording ECG, the device combines VDD pacing therapy with the capability of monitoring and recording intracardiac impedance and pressure waveforms through a temporary intracardiac lead. A PCMCIA memory card allows storage of 48 arrhythmic events of 21 seconds each. Twelve seconds of waveform are retained before the event occurs and nine seconds after. Data retrieval and processing is performed with a PC which reconstructs each waveform for display. The ECG provides data on cardiac rhythm while cardiac function is inferred from the haemodynamic signals. During simulated trials, 14 event types were presented to the system. All events were successfully detected and recorded. During in vivo clinical tests 83 waveform recordings were made. Impedance fluctuations with typical peak-to-peak values of 64 ohms were successfully recorded.

Entities:  

Mesh:

Year:  1999        PMID: 10696711     DOI: 10.1007/bf02513339

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  13 in total

1.  Acquisition of hemodynamic data and sensor signals for rate control from standard pacing electrodes.

Authors:  R Chirife
Journal:  Pacing Clin Electrophysiol       Date:  1991-11       Impact factor: 1.976

2.  Feasibility of measuring relative right ventricular volumes and ejection fraction with implantable rhythm control devices.

Authors:  R Chirife; D F Ortega; A I Salazar
Journal:  Pacing Clin Electrophysiol       Date:  1993-08       Impact factor: 1.976

3.  Right ventricular volumetry by catheter measurement of conductance.

Authors:  J C Woodard; C D Bertram; B S Gow
Journal:  Pacing Clin Electrophysiol       Date:  1987-07       Impact factor: 1.976

4.  Continuous measurement of ventricular stroke volume by electrical impedance.

Authors:  L A Geddes; H E Hoff; A Mello; C Palmer
Journal:  Cardiovasc Res Cent Bull       Date:  1966 Apr-Jun

5.  Sudden death during longterm ambulatory monitoring.

Authors:  J Roelandt; P Klootwijk; J Lubsen; M J Janse
Journal:  Eur Heart J       Date:  1984-01       Impact factor: 29.983

6.  Two monitored cases of sudden death outside hospital.

Authors:  J Pool; K Kunst; J L van Wermeskerken
Journal:  Br Heart J       Date:  1978-06

7.  Instantaneous measurement of left and right ventricular stroke volume and pressure-volume relationships with an impedance catheter.

Authors:  R G McKay; J R Spears; J M Aroesty; D S Baim; H D Royal; G V Heller; W Lincoln; R W Salo; E Braunwald; W Grossman
Journal:  Circulation       Date:  1984-04       Impact factor: 29.690

8.  Adaptive rate pacing controlled by the right ventricular preejection interval: clinical experience with a physiological pacing system.

Authors:  J H Ruiter; J P Heemels; D Kee; R van Mechelen
Journal:  Pacing Clin Electrophysiol       Date:  1992-06       Impact factor: 1.976

9.  Detecting right ventricular volume changes using the conductance catheter.

Authors:  J C Woodard; C D Bertram; B S Gow
Journal:  Pacing Clin Electrophysiol       Date:  1992-12       Impact factor: 1.976

10.  Continuous ventricular volume assessment for diagnosis and pacemaker control.

Authors:  R W Salo; B D Pederson; A L Olive; W C Lincoln; T G Wallner
Journal:  Pacing Clin Electrophysiol       Date:  1984-11       Impact factor: 1.976

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.