Literature DB >> 10695152

Sheathless capillary electrophoresis/electrospray mass spectrometry using a carbon-coated fused-silica capillary

.   

Abstract

A simple procedure was developed for preparing a carbon-coated fused-silica capillary for use in sheathless capillary electrophoresis/electrospray mass spectrometry (CE/ESI-MS). The tapered capillary tip was smeared with a marker pen before coating with carbon using a soft pencil. The layer from the ink of the marker pen was critical to the preparation of the carbon-coated capillary. The fabrication of a carbon-coated fused-silica capillary tip requires less than 1 min. The stability of this carbon-coated fused-silica capillary is examined, and its utility in on-line sheathless CE/ESI-MS is demonstrated with the separation of berberine, coptisine, and palmatine chlorides. Although the carbon-coated fused-silica capillary tip is not as rugged as a gold-coated capillary, it is durable enough for sheathless CE/ESI-MS applications. Moreover, it is easy to refurbish the column once the performance of the tip is degraded.

Entities:  

Year:  2000        PMID: 10695152     DOI: 10.1021/ac990535e

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  6 in total

1.  A fused silica micro-electrospray tip with an electrically floating metal wire insert to achieve more stable electrospray ionization.

Authors:  YunJo Chung; ChungUng Park; Joseph Kwon; Sunghwan Kim
Journal:  J Am Soc Mass Spectrom       Date:  2008-12-24       Impact factor: 3.109

Review 2.  Mass Spectrometry Approaches to Glycomic and Glycoproteomic Analyses.

Authors:  L Renee Ruhaak; Gege Xu; Qiongyu Li; Elisha Goonatilleke; Carlito B Lebrilla
Journal:  Chem Rev       Date:  2018-03-19       Impact factor: 60.622

3.  Improving the comprehensiveness and sensitivity of sheathless capillary electrophoresis-tandem mass spectrometry for proteomic analysis.

Authors:  Yueju Wang; Bryan R Fonslow; Catherine C L Wong; Aleksey Nakorchevsky; John R Yates
Journal:  Anal Chem       Date:  2012-10-05       Impact factor: 6.986

4.  Capillary Electrophoresis-Nanoelectrospray Ionization-Selected Reaction Monitoring Mass Spectrometry via a True Sheathless Metal-Coated Emitter Interface for Robust and High-Sensitivity Sample Quantification.

Authors:  Xuejiang Guo; Thomas L Fillmore; Yuqian Gao; Keqi Tang
Journal:  Anal Chem       Date:  2016-04-08       Impact factor: 6.986

5.  Capillary electrophoresis applied to proteomic analysis.

Authors:  Bryan R Fonslow; John R Yates
Journal:  J Sep Sci       Date:  2009-04       Impact factor: 3.645

6.  Capillary isotachophoresis-nanoelectrospray ionization-selected reaction monitoring MS via a novel sheathless interface for high sensitivity sample quantification.

Authors:  Chenchen Wang; Cheng S Lee; Richard D Smith; Keqi Tang
Journal:  Anal Chem       Date:  2013-07-08       Impact factor: 6.986

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.