Literature DB >> 10695148

Separation and identification of peptides from gel-isolated membrane proteins using a microfabricated device for combined capillary electrophoresis/nanoelectrospray mass spectrometry.

J Li1, J F Kelly, I Chernushevich, D J Harrison, P Thibault.   

Abstract

The coupling of microfabricated devices to nanoelectrospray mass spectrometers using both a triple quadrupole and a quadrupole time-of-flight mass spectrometer (QqTOF MS) is presented for the analysis of trace-level membrane proteins. Short disposable nanoelectrospray emitters were directly coupled to the chip device via a low dead volume connection. The analytical performance of this integrated device in terms of sensitivity and reproducibility was evaluated for standard peptide mixtures. A concentration detection limit ranging from 3.2 to 43.5 nM for different peptides was achieved in selected ion monitoring, thus representing a 10-fold improvement in sensitivity compared to that of microelectrospray using the same chip/mass spectrometer. Replicate injections indicated that reproducibility of migration time was typically less than 3.1% RSD whereas RSD values of 6-13% were observed on peak areas. Although complete resolution of individual components is not typically achieved for complex digests, the present chip capillary electrophoresis (chip-CE) device enabled proper sample cleanup and partial separation of multicomponent samples prior to mass spectral identification. Analyses of protein digests were typically achieved in less than 1.5 min with peak widths of 1.8-2.5 s (half-height definition) as indicated from individual reconstructed ion electropherograms. The application of this chip-CE/QqTOF MS system is further demonstrated for the identification of membrane proteins which form a subset of the Haemophilus influenzae proteome. Bands first separated by 1D-gel electrophoresis were excised and digested, and extracted tryptic peptides were loaded on the chip without any further sample cleanup or on-line adsorption preconcentration. Accurate molecular mass determination (< 5 ppm) in peptide-mapping experiments was obtained by introducing an internal standard via a postseparation channel. The analytical potential of this integrated device for the identification of trace-level proteins from different strains of H. influenzae is demonstrated using both peptide mass-fingerprint database searching and on-line tandem mass spectrometry.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10695148     DOI: 10.1021/ac990986z

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  7 in total

1.  Theoretical analysis of molecular diffusion in pressure-driven laminar flow in microfluidic channels.

Authors:  A E Kamholz; P Yager
Journal:  Biophys J       Date:  2001-01       Impact factor: 4.033

2.  Optical measurement of transverse molecular diffusion in a microchannel.

Authors:  A E Kamholz; E A Schilling; P Yager
Journal:  Biophys J       Date:  2001-04       Impact factor: 4.033

Review 3.  Generation of mass tags by the inherent electrochemistry of electrospray for protein mass spectrometry.

Authors:  Christophe Roussel; Loïc Dayon; Niels Lion; Tatiana C Rohner; Jacques Josserand; Joël S Rossier; Henrik Jensen; Hubert H Girault
Journal:  J Am Soc Mass Spectrom       Date:  2004-12       Impact factor: 3.109

4.  Fully integrated glass microfluidic device for performing high-efficiency capillary electrophoresis and electrospray ionization mass spectrometry.

Authors:  J S Mellors; V Gorbounov; R S Ramsey; J M Ramsey
Journal:  Anal Chem       Date:  2008-08-13       Impact factor: 6.986

5.  Analytical performance of a venturi-assisted array of micromachined ultrasonic electrosprays coupled to ion trap mass spectrometry for the analysis of peptides and proteins.

Authors:  Christina Y Hampton; Thomas P Forbes; Mark J Varady; J Mark Meacham; Andrei G Fedorov; F Levent Degertekin; Facundo M Fernández
Journal:  Anal Chem       Date:  2007-10-03       Impact factor: 6.986

6.  MANF: a new mesencephalic, astrocyte-derived neurotrophic factor with selectivity for dopaminergic neurons.

Authors:  Penka Petrova; Andrei Raibekas; Jonathan Pevsner; Noel Vigo; Mordechai Anafi; Mary K Moore; Amy E Peaire; Viji Shridhar; David I Smith; John Kelly; Yves Durocher; John W Commissiong
Journal:  J Mol Neurosci       Date:  2003-04       Impact factor: 3.444

Review 7.  Microfluidic chip-based technologies: emerging platforms for cancer diagnosis.

Authors:  Li Ying; Qi Wang
Journal:  BMC Biotechnol       Date:  2013-09-27       Impact factor: 2.563

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.