Literature DB >> 10694526

Permanent, direct His-bundle pacing: a novel approach to cardiac pacing in patients with normal His-Purkinje activation.

P Deshmukh1, D A Casavant, M Romanyshyn, K Anderson.   

Abstract

BACKGROUND: Direct His-bundle pacing (DHBP) produces synchronous ventricular depolarization and improved cardiac function relative to apical pacing. Although it has been performed transiently in the electrophysiology laboratory and persistently in open-chested canines, permanent DHBP in humans has not been achieved. METHODS AND
RESULTS: A total of 18 patients aged 69+/-10 years who had a history of chronic atrial fibrillation, dilated cardiomyopathy, and normal activation (ie, QRS< or =120 ms) were screened for permanent DHBP using an electrophysiology catheter. In 14 patients, the His bundle could be reliably stimulated. Of these 14, permanent DHBP using a fixed screw-in lead was successful in 12 patients. Radiofrequency atrioventricular node ablation was performed in patients exhibiting a fast ventricular response. All patients received single-chamber rate-responsive pacemakers. Acute pacing thresholds were 2.4+/-1.0 V at a pulse duration of 0.5 ms. Lead complications included exit block requiring reoperative adjustment and gross lead dislodgment. Echocardiographic improvement in heart function was shown by reductions in the left ventricular end-diastolic dimension from 59+/-8 to 52+/-6 mm (P</=0.01) and in the end-systolic dimension from 51+/-10 to 43+/-8 mm (P<0.01), with an accompanying increase in fractional shortening from 14+/-7% to 20+/-10% (P=0.05). The left ventricular ejection fraction improved from 20+/-9% to 31+/-11% (P<0. 01), and the cardiothoracic ratio decreased from 0.61+/-0.06 to 0. 57+/-0.07 (P<0.01). Despite DHBP, 2 patients died at 8 and 36 months. Conclusions-Permanent DHBP is feasible in select patients who have chronic atrial fibrillation and dilated cardiomyopathy. Long-term, DHBP results in a reduction of left ventricular dimensions and improved cardiac function.

Entities:  

Mesh:

Year:  2000        PMID: 10694526     DOI: 10.1161/01.cir.101.8.869

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  99 in total

1.  Permanent direct his bundle pacing does not induce ventricular dyssynchrony unlike conventional right ventricular apical pacing. An intrapatient acute comparison study.

Authors:  Domenico Catanzariti; Massimiliano Maines; Claudio Cemin; Gianpaolo Broso; Tiziana Marotta; Giuseppe Vergara
Journal:  J Interv Card Electrophysiol       Date:  2006-11-18       Impact factor: 1.900

Review 2.  Role of resynchronisation therapy and implantable cardioverter defibrillators in heart failure.

Authors:  S Ellery; L Williams; M Frenneaux
Journal:  Postgrad Med J       Date:  2006-01       Impact factor: 2.401

3.  Feasibility of his bundle pacing as an alternative pacing site: measurement of his refractoriness.

Authors:  Lorne J Gula; Geoffrey M Trim; Andrew D Krahn; Allan C Skanes; Raymond Yee; George J Klein
Journal:  J Interv Card Electrophysiol       Date:  2005-01       Impact factor: 1.900

4.  Future easy and physiological cardiac pacing.

Authors:  Eraldo Occhetta; Miriam Bortnik; Paolo Marino
Journal:  World J Cardiol       Date:  2011-01-26

Review 5.  Direct His bundle and paraHisian cardiac pacing.

Authors:  Francesco Zanon; S S Barold
Journal:  Ann Noninvasive Electrocardiol       Date:  2012-04       Impact factor: 1.468

Review 6.  [His-bundle stimulation and alternative RV stimulation sites].

Authors:  G Fröhlig; M Kindermann
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2008-03

7.  Selective site pacing: rationale and practical application.

Authors:  Sameer Parekh; Kenneth M Stein
Journal:  Curr Cardiol Rep       Date:  2008-09       Impact factor: 2.931

8.  Chronic left ventricular pacing preserves left ventricular function in children.

Authors:  Irene E van Geldorp; Ward Y Vanagt; Urs Bauersfeld; Maren Tomaske; Frits W Prinzen; Tammo Delhaas
Journal:  Pediatr Cardiol       Date:  2008-08-15       Impact factor: 1.655

9.  Fifty years of cardiac pacing: the dark side of the moon?

Authors:  C C de Cock
Journal:  Neth Heart J       Date:  2008-10       Impact factor: 2.380

10.  Atrioventricular Nodal Catheter Ablation in Atrial Fibrillation Complicating Congestive Heart Failure.

Authors:  Osmar Antonio Centurión; Karina Elizabeth Scavenius; Laura B García; Luis Miño; Judith Torales; Orlando Sequeira
Journal:  J Atr Fibrillation       Date:  2018-06-30
View more