Literature DB >> 10694522

Transcatheter closure of atrial septal defects without fluoroscopy: feasibility of a new method.

P Ewert1, F Berger, I Daehnert, J van Wees, M Gittermann, H Abdul-Khaliq, P E Lange.   

Abstract

BACKGROUND: In an effort to reduce x-ray exposure, we developed a technique for transcatheter closure of atrial septal defects under echocardiographic guidance without fluoroscopy. To assess the efficiency of this procedure for routine use, we compared our initial results with those for the conventional procedure. METHODS AND
RESULTS: Twenty-two randomly selected patients (median age 18 years; range 2 to 66 years) with atrial septal defects (n=13) or patent foramen ovale (n=9) underwent cardiac catheterization for possible interventional defect closure with echocardiography as the only imaging tool. Median stretched diameter was 9 mm (range 6 to 26 mm); median left-to-right shunt over the atrial septal defects was Qp/Qs=1.8 (range 1.5 to 2.6). An Amplatzer septal occluder was successfully implanted in 19 defects without fluoroscopy and in 3 with the help of radiography. After 1 month, complete defect closure was documented in all patients. Compared with the conventional procedure of a control group of 131 patients, procedure times were not significantly different (88 versus 100 minutes; P=0.09). However, the study group received significantly higher doses of propofol for sedation (9.9 versus 5.6 mg/kg body weight; P=0.002) owing to extended transesophageal echocardiography.
CONCLUSIONS: In the majority of patients in whom transcatheter closure of interatrial communications with the Amplatzer septal occluder is possible, the procedure can be safely performed under echocardiographic guidance without fluoroscopy.

Entities:  

Mesh:

Year:  2000        PMID: 10694522     DOI: 10.1161/01.cir.101.8.847

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  20 in total

1.  Total endoscopic robotic atrial septal defect repair in a patient with dextrocardia and situs inversus totalis.

Authors:  Kenji Iino; Go Watanabe; Norihiko Ishikawa; Shigeyuki Tomita
Journal:  Interact Cardiovasc Thorac Surg       Date:  2011-12-26

Review 2.  Clinical applications of intracardiac echocardiography in interventional procedures.

Authors:  M R M Jongbloed; M J Schalij; K Zeppenfeld; P V Oemrawsingh; E E van der Wall; J J Bax
Journal:  Heart       Date:  2005-07       Impact factor: 5.994

3.  Assessment of atrial septum morphology by live three-dimensional echocardiography.

Authors:  Lingyun Fang; Mingxing Xie; Xinfang Wang
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2007-12

4.  Persistence of the eustachian valve in secundum atrial septal defects: possible implications for cerebral embolism and transcatheter closure procedures.

Authors:  J M Strotmann; W Voelker; P Schanzenbaecher
Journal:  Heart       Date:  2001-07       Impact factor: 5.994

Review 5.  Patent foramen ovale (PFO), stroke and pregnancy.

Authors:  Lei Chen; Wenjun Deng; Igor Palacios; Ignacio Inglessis-Azuaje; David McMullin; Dong Zhou; Eng H Lo; Ferdinando Buonanno; MingMing Ning
Journal:  J Investig Med       Date:  2016-03-17       Impact factor: 2.895

Review 6.  Challenges encountered during closure of atrial septal defects.

Authors:  W Knirsch; A Dodge-Khatami; E Valsangiacomo-Buechel; M Weiss; F Berger
Journal:  Pediatr Cardiol       Date:  2005 Mar-Apr       Impact factor: 1.655

Review 7.  [Echocardiography during transcatheter interventions. New developments].

Authors:  J Balzer
Journal:  Herz       Date:  2013-02       Impact factor: 1.443

8.  Closure of defects of the atrial septum in adults using the Amplatzer device: 100 consecutive patients in a single center.

Authors:  I F Purcell; S J Brecker; D E Ward
Journal:  Clin Cardiol       Date:  2004-09       Impact factor: 2.882

9.  Safe and efectivef guidance by intracardiac echocardiography for transcatheter closure in atrial septal defects.

Authors:  Yu Wang; Tao Guo; Guizheng Liang; Ling Zhao; Jiahua Pan; Shumin Li; Baotong Hua; Lijin Pu
Journal:  Int J Clin Exp Med       Date:  2015-05-15

10.  Safe and effective guidance by intracardiac echocardiography for transcatheter closure in atrial septal defects.

Authors:  Jing Zhao; Li Li; Ling Peng
Journal:  Int J Clin Exp Med       Date:  2015-06-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.