Günther Tulip filter: preliminary clinical experience with retrieval.

S F Millward1, A Bhargava, J Aquino, R A Peterson, J P Veinot, J Bormanis, P S Wells.   

Abstract

PURPOSE: The Günther Tulip filter is a permanent filter that has a hook to permit retrieval. The authors report their preliminary clinical evaluation of the filter with regard to feasibility and safety of retrieval.
MATERIALS AND METHODS: Nine men and six women who ranged in age from 17 to 79 years (mean, 51 years) underwent treatment with use of the Günther Tulip filter. Patients judged to require caval interruption for < 14 days were selected to receive the filter and retrieval was planned for all patients. Indications for filter placement were: recent pulmonary embolism (PE) or proximal deep vein thrombosis (DVT) with a contraindication to anticoagulation (11 patients), massive PE treated with thrombolytic therapy (one patient), PE with heparin-induced thrombocytopenia (one patient), and prophylaxis after major trauma (two patients). Patients were followed for inferior vena cava (IVC) thrombosis, bleeding, and recurrent DVT or PE.
RESULTS: In all nine patients in whom it was attempted, the filter was successfully snared and retrieved via a jugular approach. The mean implantation period was 8.6 days (range, 5-13 days). Retrieval required 2.2-13 minutes (mean 5.3 minutes) of fluoroscopy. No caval injuries occurred as a result of retrieval. All retrieved filters had strands of organized thrombus on the filter struts. The patients were followed for 52-285 days (mean, 115 days) after retrieval. One patient developed a recurrent DVT 230 days after retrieval. No other patients developed a recurrent DVT and no patients developed IVC thrombosis, bleeding, or PE. Six filters were not retrieved: five because of an ongoing contraindication to anticoagulation and one because the patient died of causes unrelated to the filter.
CONCLUSION: This preliminary study confirms the feasibility and safety of retrieval of the Günther Tulip filter up to 13 days after implantation.

Entities:  

Mesh:

Year:  2000        PMID: 10693717     DOI: 10.1016/s1051-0443(07)61286-x

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  8 in total

1.  Complications of inferior vena caval filters.

Authors:  Thuong G Van Ha
Journal:  Semin Intervent Radiol       Date:  2006-06       Impact factor: 1.513

2.  The use of retrievable inferior vena cava filters in the trauma population.

Authors:  Kristina Spate; Faisal Aziz; Bauer E Sumpio
Journal:  Int J Angiol       Date:  2008

3.  Complications related to deep venous thrombosis prophylaxis in trauma: a systematic review of the literature.

Authors:  Indraneel Datta; Chad G Ball; Lucas Rudmik; S Morad Hameed; John B Kortbeek
Journal:  J Trauma Manag Outcomes       Date:  2010-01-06

4.  Thromboembolism after trauma: an analysis of 1602 episodes from the American College of Surgeons National Trauma Data Bank.

Authors:  M Margaret Knudson; Danagra G Ikossi; Linda Khaw; Diane Morabito; Larisa S Speetzen
Journal:  Ann Surg       Date:  2004-09       Impact factor: 12.969

5.  Prophylactic Implantation of Inferior Vena Cava Filter during Endovascular Therapies for Deep Venous Thrombosis of the Lower Extremities.

Authors:  Takuji Yamagami; Tsunehiko Nishimura
Journal:  Ann Vasc Dis       Date:  2011-02-17

6.  Günther-Tulip inferior vena cava filter removal 3334 days after placement.

Authors:  Benjamin B Lind; Hector Ferral
Journal:  J Vasc Surg Cases       Date:  2015-03-16

7.  Venous thromboembolism after removal of retrievable inferior vena cava filters.

Authors:  Takuji Yamagami; Osamu Tanaka; Rika Yoshimatsu; Hiroshi Miura; Tsunehiko Nishimura
Journal:  Cardiovasc Intervent Radiol       Date:  2009-09-19       Impact factor: 2.740

8.  Successful removal of a Gunther tulip vena cava filter with wall-embedded hook and migration during a retrieval attempt.

Authors:  Takuji Yamagami; Rika Yoshimatsu; Tomohiro Matsumoto; Tsunehiko Nishimura
Journal:  Acta Radiol Short Rep       Date:  2013-02-28
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.