New ultrasound approaches to dialysis access monitoring.

M Paun1, K Beach, S Ahmad, R Hickman, M Meissner, C Plett, D E Strandness.   

Abstract

The failure of dialysis access is a frequent source of morbidity and hospitalization. Traditional methods of graft surveillance include: (1) clinical examination, (2) venous line pressure measurements during dialysis, (3) urea or tracer recirculation measurement, (4) continuous wave (CW) Doppler methods, (5) duplex ultrasonography, and (6) radiograph angiography. All these methods require special training and/or laboratory tests. The purpose of this study was to test a simple continuous-wave Doppler method that could be applied to measure the flow rate in dialysis access every time the patient undergoes dialysis. Twenty dialysis patients, 15 with polytetrafluoroethylene grafts and 5 with arteriovenous fistulae, were studied. Two hundred fifty-three examinations were performed over an 8-month period. Doppler waveforms of the access flow were obtained with the pump on, with the pump off, and with the pump on again. Systolic and diastolic Doppler frequency measurements were made, and the pump-on and pump-off measurements were compared. In an access functioning normally, the Doppler frequencies are higher with the pump off than with the pump on. In 22% of the cases, there were abnormal findings in which the Doppler frequencies were lower with the pump off than with the pump on. This occurs if the needles are incorrectly placed, suggesting that recirculation is occurring. Recirculation also occurs if there is stenosis of the access. Examining the hemodialysis access during each dialysis session with an inexpensive directional Doppler may identify a significant stenosis and improve the efficiency of dialysis by detecting those patients in whom the arterial and venous needles are reversed.

Entities:  

Mesh:

Year:  2000        PMID: 10692274     DOI: 10.1016/s0272-6386(00)70201-0

Source DB:  PubMed          Journal:  Am J Kidney Dis        ISSN: 0272-6386            Impact factor:   8.860


  2 in total

1.  The relationship between arteriovenous fistula blood flow rate and pulmonary artery pressure in hemodialysis patients.

Authors:  Gursel Acarturk; Ramazan Albayrak; Mehmet Melek; Seref Yuksel; Ihsan Uslan; Huseyin Atli; Mehmet Colbay; Mehmet Unlu; Fatma Fidan; Zerrin Asci; Soner Cander; Ozcan Karaman; Murat Acar
Journal:  Int Urol Nephrol       Date:  2008       Impact factor: 2.370

2.  Far infrared therapy inhibits vascular endothelial inflammation via the induction of heme oxygenase-1.

Authors:  Chih-Ching Lin; Xiao-Ming Liu; Kelly Peyton; Hong Wang; Wu-Chang Yang; Shing-Jong Lin; William Durante
Journal:  Arterioscler Thromb Vasc Biol       Date:  2008-01-17       Impact factor: 8.311

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.