Literature DB >> 10692131

Analysis of spherical aberration of a water immersion objective: application to specimens with refractive indices 1.33-1.40.

D S Wan1, M Rajadhyaksha, R H Webb.   

Abstract

The method of using immersion medium to correct spherical aberration for water immersion objectives when the samples are not water is investigated. Spherical aberration is measured by an interferometer converted from a confocal microscope for samples with different refractive indices. When the proper refractive index of the immersion medium and thickness of cover slip are selected, the measured spherical aberration approaches zero. A theoretical model can be used for prediction of the immersion medium to correct spherical aberration for various samples. Using the thinnest available cover slip (100 microm), the zero spherical aberration condition can be applied to samples with refractive index as high as 1.40. Confocal images in the condition of almost no spherical aberration are included to demonstrate the improvement of axial resolution due to this correction.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10692131     DOI: 10.1046/j.1365-2818.2000.00635.x

Source DB:  PubMed          Journal:  J Microsc        ISSN: 0022-2720            Impact factor:   1.758


  7 in total

1.  Adaptive aberration correction in a confocal microscope.

Authors:  Martin J Booth; Mark A A Neil; Rimas Juskaitis; Tony Wilson
Journal:  Proc Natl Acad Sci U S A       Date:  2002-04-16       Impact factor: 11.205

2.  Adaptive optical versus spherical aberration corrections for in vivo brain imaging.

Authors:  Raphaël Turcotte; Yajie Liang; Na Ji
Journal:  Biomed Opt Express       Date:  2017-07-31       Impact factor: 3.732

3.  Motion quantification during multi-photon functional imaging in behaving animals.

Authors:  Lingjie Kong; Justin P Little; Meng Cui
Journal:  Biomed Opt Express       Date:  2016-08-26       Impact factor: 3.732

Review 4.  The use of reflectance confocal microscopy for examination of benign and malignant skin tumors.

Authors:  Dorota Wielowieyska-Szybińska; Kamila Białek-Galas; Katarzyna Podolec; Anna Wojas-Pelc
Journal:  Postepy Dermatol Alergol       Date:  2014-12-03       Impact factor: 1.837

5.  Giemsa-stained wet mount based method for reticulocyte quantification: a viable alternative in resource limited or malaria endemic settings.

Authors:  Wenn-Chyau Lee; Bruce Russell; Yee-Ling Lau; Mun-Yik Fong; Cindy Chu; Kanlaya Sriprawat; Rossarin Suwanarusk; Francois Nosten; Laurent Renia
Journal:  PLoS One       Date:  2013-04-02       Impact factor: 3.240

6.  Methanol immersion reduces spherical aberration of water dipping lenses at long wavelengths used in multi-photon laser scanning microscopy.

Authors:  Greg Norris; Ayman Gebril; Valerie A Ferro; Gail McConnell
Journal:  Biomed Opt Express       Date:  2012-11-21       Impact factor: 3.732

7.  4Pi-RESOLFT nanoscopy.

Authors:  Ulrike Böhm; Stefan W Hell; Roman Schmidt
Journal:  Nat Commun       Date:  2016-02-01       Impact factor: 14.919

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.